Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
The abnormalities in initialization of
the focus lens and the abnormalities in
E
6
1
1
1
initialization of the zoom lens occurred
simultaneously.
Reset position detection error on the step-
E
6
1
3
0
per iris initializing
Handshake correction function does not
E
6
2
0
0
work well. (With PITCH angular velocity
sensor output stopped.)
Handshake correction function does not
E
6
2
0
1
work well. (With YAW angular velocity
sensor output stopped.)
E
6
2
0
2
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
E
6
2
0
3
communication abnormality among.
Image vibration correction during hand-
E
6
2
0
4
shake function does not work.
E
6
2
1
0
Shift lens initializing failure.
E
6
2
1
1
Shift lens overheating (Pitch)
E
6
2
1
2
Shift lens overheating (Yaw)
E
6
2
2
0
Abnormality of thermistor.
E
6
2
3
0
Abnormal CPU
E
9
1
0
1
Abnormality when flash is being charged.
*
E
9
1
0
2
Abnormality of LED Video light.
*
Abnormality of LED Video light Tem-
E
9
1
0
3
*
perature detection.
Battery current value goes over the max
E
9
2
0
1
discharge current
Fault of writing or erasing the flash
E
9
4
0
0
memory
E
9
4
0
1
Internal flash memory fault
E
9
4
0
2
BGM data error
E
9
5
0
0
*
GPS hardware error
E
9
6
0
0
*
Map area mount error
E
9
7
0
0
Projector hardware error
Note 2: Functions of codes with * mark are not provided in this unit.
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
HDR-CX330/CX330E/PJ330E/PJ340/PJ340E/PJ350/PJ350E_L2
Correction
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Turn the power on to open lens barrier. Disconnect the battery or power
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens drive
block (pin wg, wh of CN4002 on theVC-1025 board).
If iris blades work normally, confirm that they are closing completely
and confirm following item.
• Case of the iris blades do not close normally. Replace the lens block.
• Case of E: "61: 30" is appeared and iris blades closed completely.
Confirm that communication with lens block is normal.
• Case of LCD is not displayed normally. Check that connection between
CN6702 on CM-1004 board and CN4004 on VC-1025 board by FP-
2190 flexible board.
• Case of LCD is displayed normally. Replace the lens block.
Inspect PITCH angular velocity sensors (SE7701 on the JK-1009 board)
peripheral circuits.
Inspect YAW angular velocity sensors (SE7701 on the JK-1009 board)
peripheral circuits.
Refer to "1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Occurred".
Inspect the steadyshot circuit (IC7711 on the VC-1025 board).
Inspect the image vibration angular velocity sensors (SE7711 on the VC-
1025 board) peripheral circuits.
Replacement of lens block (Note 3).
If an error occurs again, replace the VC-1025 board.
Refer to "1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred".
Refer to "1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred".
Refer to "1-5-4. E : 62 : 20 (Abnormality of Thermistor) Occurred".
Turn power off and turn power on again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Check the remaining battery power because this symptom maybe de-
pended on the remaining battery level, and confirm whether or not the
symptom is occurred after replacing the battery. If the symptom is still
occurred, overhaul inspection is needed. Check each output of DC/DC
converter (IC5100 on the VC-1025 board) with connected the DC JACK
(CN4007) on the VC-1025 board.
(The minimum connection to periphery)
Inspect the flash memory (IC8101 on the MM-102 board).
Inspect the flash memory (IC8101 on the MM-102 board).
Check the CPU (IC6000 on the VC-1025 board).
Turn power off and turn power on again.
Turn power off and turn power on again.
Turn power off and turn power on again.

1-5. METHOD OF COPING WITH SHIFT LENS ERROR

VC-1025 BOARD (SIDE A)
IC6800
Measurement points on the VC-1025 board
Note: The length of low section will vary a little depending on the conditions.
Change in output voltage of R1401 on the VC-1025 board
1-3
R1401
Fig. 1
approx. 330 msec
Fig. 2