8.4

Component access

Removing bottom panel
1. Push in the clip securing the bottom panel.
2. Pull bottom panel sidewards to release from service position and
remove.
1.
2.
Fig. 77 Removing bottom panel
Greenstar 8000 Life – 6720883865 (2021/11)
1.
2.
2.
0010023671-003
Removing front cover
1. Remove screw from bottom of front panel.
2. Push in the green clips securing both sides the outer case.
3. Pull bottom of front cover forwards and upwards to release the clip on
top of the boiler and remove outer case.
Fig. 78 Removing outer case
Inspection and maintenance
3.
1.
2.
2.
0010019013-001
61