Worcester Greenstar 8000 Life Installation And Maintenance Instructions Manual page 58

Gas fired condensing combi boiler
Hide thumbs Also See for Greenstar 8000 Life:
Table of Contents

Advertisement

Settings in the service menu
Service function L.4
4-d1 Automatic filling
4-d2 Minimum system pressure
4-d3 Target system pressure
4-d4 Max. refilling time
4-d7 Reset refilling
4-d8 Heating system type
4-d9 Manual fill
4-F1 Reset appliance to basic setting
4-F2 Reset of maintenance message
Table 23 Menu 4: Settings
Menu 5 (L.5): Limit values
▶ Press the ( key and * key at the same time, until L.A is displayed.
▶ Keep pressing the  key, until L.5 is displayed.
▶ To confirm the selection: Press the ok key.
▶ Select and set the service function.
Service function L.5
5-A1 Maximum flow temperature
5-A2 Maximum DHW temperature
5-A3 Minimum boiler output (heating and
DHW)
Table 24 Menu 5: Limit values
58
Settings/adjustment range
• OFF
• ON
• 0.6 ... 0.7 ... 0.8 bar
• 1.0 ... 1.7 bar
• 120 ... 240 s
• YES/NO
• 0: Small
• 1: Medium
• 2: Large
• YES/NO
• NO: Settings are retained
• YES: Appliance is reset to basic settings
• NO
• YES
The basic settings are depicted as highlighted in the following table.
Settings/adjustment range
• 30 ... 88 °C
• 35 ... 60 °C
• 10 ... 50%
Remark/restriction
This service function is only available, if service
function 4-b0 is activated.
4-d0 to 4-d9: When optional intelligent filling
system is installed.
The automatic filling function ensures that the
operating pressure is maintained. If the operating
pressure drops below the set value, the filling valve
opens until the set pressure is reached.
To protect against e.g. leakage, the filling valve
closes in the following cases:
• No pressure increase can be measured.
• The set filling time is exceeded.
Small: < 8 radiators
Medium: 8 – 15 radiators
Large: > 15 radiators
Only available if the max. number of fills has been
reached. Before use, ensure there is no water
escaping from the heating system.
Remark/restriction
Limits the adjustment range for the flow
temperature.
Limits the adjustment range for the hot water
temperature.
Minimum heat output.
Greenstar 8000 Life – 6720883865 (2021/11)

Hide quick links:

Advertisement

Table of Contents
loading