8.9.5

Checking electrodes

▶ Remove the electrode set with gasket.
▶ Check electrodes for contamination.
▶ Clean or replace electrodes if required.
▶ Install electrode set with new gaskets.
▶ Ensure the screws are fully tightened.
Fig. 94 Installing electrode set
▶ Check integrity of seal of electrode set. Using a mirror to check for
misting.
Gas/Gaz?
Fig. 95 Checking for leaks with an inspection mirror. Observe for
misting.
Greenstar 8000 Life – 6720883865 (2021/11)
8.9.6

Cleaning the siphon

Cleaning the condensate trap
WARNING
Danger to life due to poisoning!
If the condensate trap is not filled, poisonous flue gas can escape.
▶ Only turn off the siphon filling program during maintenance, and turn
it back on at the end of maintenance.
▶ Make sure that the condensate drains off properly.
Damages resulting from an insufficiently cleaned condensate trap are
excluded from the warranty.
▶ Clean the condensate trap regularly.
1. Whilst supporting the condensate trap, firmly press the unlock
mechanism, until an audible click is heard.
2. Pull the condensate trap forwards and tilt to the left for draining.
0010026738-001
3. Once empty pull the hose from the condensate trap.
0010007499-003
Fig. 96 Removing the condensate trap
▶ Remove the condensate trap.
▶ Clean the condensate trap, and check that the aperture towards the
heat exchanger is clear.
▶ Remove the gasket on the top of the condensate trap.
▶ Check the gasket for cracks, deformation or breakage and replace if
required.
Inspection and maintenance
1.
2.
3.
0010017101-001