NOTES
"Typ." value means the average current consumption value.
1)
1.
"Rock Bottom Sleep" means the operation is performed with AT+CFUN=0 and AT+QSLCK=1 (DTR
2)
2.
pin at high level).
3)
3.
Sleep state with UART connected and USB disconnected. The module can enter sleep mode
through executing AT+QSCLK=1 command via UART interface and then controlling the module's
DTR pin. For details, please refer to Chapter 3.4.4.
4. LTE-FDD B25 is supported on BG96 of R1.2 hardware version.
Table 35: GNSS Current Consumption
Description
Searching
(AT+CFUN=0)
Tracking
(AT+CFUN=0)

6.5. RF Output Power

The following table shows the RF output power of BG96 module.
Table 36: BG96 RF Output Power
Frequency
LTE-FDD B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/
B26/B28
LTE-TDD B39
GSM850/EGSM900
DCS1800/PCS1900
GSM850/EGSM900 (8-PSK)
BG96_Hardware_Design
Conditions
Cold Start @Passive Antenna
Lost State @Passive Antenna
Instrument Environment
Open Sky @Passive Antenna
Open Sky @Active Antenna
LPWA Module Series
BG96 Hardware Design
Typ.
Unit
41.7
mA
42
mA
21.7
mA
36
mA
35
mA
Max.
Min.
23dBm± 2dB
<-39dBm
23dBm± 2dB
<-39dBm
33dBm± 2dB
5dBm± 5dB
30dBm± 2dB
0dBm± 5dB
27dBm± 3dB
5dBm± 5dB
62 / 79