READ AND FOLLOW SAFETY IMPORTANT INSTRUCTIONS! SAFETY INSTRUCTIONS This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert Always follow basic safety pre- to the potential for personal injury.
INSTALLATION Only qualified, licensed personnel should install pump and wiring. Pump mount must: Be solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Allow pump suction inlet height to be as close to water level as possible. Allow use of short, direct suction pipe (To reduce friction losses).
POOL PUMP SUCTION REQUIREMENTS Pump suction is hazardous and can trap and drown or disem- bowel bathers. Do not use or operate swimming pools, spas, or hot tubs if a suction outlet cover is missing, broken, or loose. Follow the guidelines below for a pump installation which minimizes risk to users of pools, spas, and hot tubs.
Page 5
The system must be built so that it cannot operate with the pump drawing water from only one main drain (that is, there must be at least two main drains connected to the pump whenever it is running). However, if two main drains run into a single suction line, the single suction line may be equipped with a valve which will shutoff both main drains from the pump.
Page 6
Grounding/Bonding BONDING Install, ground, bond and wire motor according to local or National Electrical Code requirements. Permanently ground motor. Use green ground terminal provided under motor canopy or access plate (See Figure 2); use size and type wire required by GREEN code.
OPERA TION NOTICE: Maximum operating pressure is 50 PSI. NOTICE: NEVER run pump dry. Running pump dry may damage seals, caus- ing leakage and flooding. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2.
To avoid condensation/corrosion problems, do not cover pump with plastic. For outdoor/unprotected installations: 1. Gravity drain system as far as possible. 2. Protect areas which retain water with non-toxic propylene glycol antifreeze (“RV antifreeze”). 3. Enclose entire system in a weatherproof enclosure. 4.
Page 9
To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before working on pump or motor. If shaft seal is worn or damaged, repair as follows: Removal of Old Seal 1. Remove drain plug (Key No. 12 in exploded view, Page 11) and drain pump.
TROUBLESHOOTING GUIDE Read and understand safety and operating instructions in this manual before doing any work on pump! Only qualified personnel should electrically test pump motor! FAILURE TO PUMP; REDUCED CAPACITY OR DISCHARGE PRESSURE Suction leaks/lost prime: 1. Pump must be primed; make sure that pump volute is full of water. See priming instructions, Page 7.
REPAIR PARTS LIST 1/2 through 1-1/2 HP Models JHSC-61USF JHSD-62USF JHSE-63USF JHSF-51USF 3551 1099 Parts are common to all models listed except as noted; Part Part Motor (Key No. 1) and Impeller (Key No. 9) are listed below. Description Qty.
Page 12
The foregoing warranties relate to the original consumer pur- chaser (“Purchaser”) only. Sta-Rite shall have the option to re- HRPB, DEPB, System 3, and PL – Tanks ..10 years pair or replace the defective product, at its sole discre- Internal filter components and valves .
Need help?
Do you have a question about the JHSC-61USF and is the answer not in the manual?