PERFORMANCE VERIFICATION PROCEDURE

Purpose

Equipment
Required

Software Required

Procedure

Racal Instruments  1998
The following procedure verifies the basic functions of the
1260-100/101 Adapt-a-Switch Carrier. Test coverage includes:
• Option-01T power-on self-test
• Option-01T basic operation in message based mode
• Option-01T operation in register-based mode
• 1260-100/101 receive and transmit functions
• VXIbus chassis
• Embedded slot 0 controller, or MXI slot 0 controller with
IBM-compatible PC
• Microsoft Windows 95 or NT
• VXI Resource Manager (RESMAN) by National Instruments
• VXI Interactive Control (VIC) by National Instruments
1. Ensure that an Option-01T is installed in the carrier as
outlined in the Option-01T section of Chapter 2: Getting
Started .
2. Set the logical address switch to 3.
3. Set the module address switch to the 1-6 position.