A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
• C r i t i c a l a n d e x p e d i t e d s e r v i c e s
• I n s t o c k / R e a d y - t o - s h i p
Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate, representative, or authorized distributor for any manufacturer listed herein.
In Stock
Used and in Excellent Condition
Buy Today!
https://www.artisantg.com/66920-2
• We b u y y o u r e x c e s s , u n d e r u t i l i z e d , a n d i d l e e q u i p me n t
• F u l l - s e r v i c e , i n d e p e n d e n t r e p a i r c e n t e r
Summary of Contents for Racal Instruments 1260-37A
Page 1
Racal 1260-37A Multiplexer Module In Stock Used and in Excellent Condition Buy Today! https://www.artisantg.com/66920-2 A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
RACAL INSTRUMENTS 1260-37 SWITCH MODULE PUBLICATION NO. 980673-024 EADS North America Defense Test and Services, Inc. 4 Goodyear, Irvine, CA 92618 Tel: (800) 722-2528, (949) 859-8999; Fax: (949) 859-7139 info@eads-nadefense.com sales@eads-nadefense.com helpdesk@eads-nadefense.com http://www.eads-nadefense.com PUBLICATION DATE: December 11, 2000 Copyright 1994 by EADS North America Defense Test and Services, Inc. Printed in the United States of America. All rights reserved.
THANK YOU FOR PURCHASING THIS EADS NORTH AMERICA DEFENSE TEST AND SERVICES PRODUCT For this product, or any other EADS North America Defense Test and Services, Inc. product that incorporates software drivers, you may access our web site to verify and/or download the latest driver versions. The web address for driver downloads is: http://www.eads-nadefense.com/downloads If you have any questions about software driver downloads or our privacy policy, please contact us at...
RETURN of PRODUCT Authorization is required from EADS North America Defense Test and Services, Inc. before you send us your product for service or calibration. Call or contact the Customer Support Department at 1-800-722-3262 or 1- 949-859-8999 or via fax at 1-949-859-7139. We can be reached at: helpdesk@eads-nadefense.com. PROPRIETARY NOTICE This document and the technical data herein disclosed, are proprietary to EADS North America Defense Test and Services, Inc., and shall not, without express written permission of EADS North America Defense Test...
FOR YOUR SAFETY Before undertaking any troubleshooting, maintenance or exploratory procedure, read carefully the WARNINGS and CAUTION notices. This equipment contains voltage hazardous to human life and safety, and is capable of inflicting personal injury. If this instrument is to be powered from the AC line (mains) through an autotransformer, ensure the common connector is connected to the neutral (earth pole) of the power supply.
Page 7
This page was left intentionally blank. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 8
1260-37 User Manual NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax” section of this manual shows the command syntax for the 1260-01S Smart Card. If you are using the newer 1260-01T Smart Card, the commands will NOT work as shown.
Page 9
Control Information for the 1260-37A The following information describes the control-register-to-relay-channel mapping for a 1260-37A Relay Module. This information may be used to control a 1260-37A when using a 1260-01T in the register-based mode of operation. The table below shows the mapping between logical channels used to operate the relay module in message-based mode and the bits within the Control Registers which may be used to operate the channel in register-based mode.
Page 10
1260-37 User Manual Channel Control Register Control Bit Addendum Page 6/98 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 11
1260-37 User Manual Control Information for the 1260-37B The following information describes the control-register-to-relay-channel mapping for a 1260-37B Relay Module. This information may be used to control a 1260-37B when using a 1260-01T in the register-based mode of operation. Each relay on this module is controlled by setting or clearing a single bit. Control Registers on the module operate 8 channels simultaneously.
Page 12
1260-37 User Manual Channel Control Register Control Bit Addendum Page 6/98 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 13
1260-37 User Manual This page was left intentionally blank. 6 Addendum Page 6/98 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 16
1260-37 User Manual List of Figures Figure 1-1, 1260-37 Switching Card ....................1-1 Figure 3-1, 1260-37 Multiplexer/Scanner Circuit Block Diagram ............ 3-7 Figure 3-2, 1260-37 40-Channel SPDT Circuit Block Diagram............3-8 Figure 3-3, 1260-37 Pin Connections ..................... 3-9 List of Tables Table 2-1, 1260-37 Multiplexer/Scanner Circuit Jumper Installation ..........
Page 17
1260-37 User Manual This page was left intentionally blank. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
1260-37 User Manual Chapter 1 MODULE SPECIFICATION The 1260-37 switch module consists of two switch circuits; a 1 x 1260-37 Module 48 Signal Multiplexer/Scanner and a 40-Channel SPDT Switch. Specification The Signal Multiplexer circuit switches two lines per channel, and has the capability of being configured as one 1 x 48 multiplexer, two 1 x 24 multiplexers, four 1 x 12 multiplexers, or eight 1 x 6 multiplexers.
1260-37 User Manual 1 x 48 Signal Multiplexer/Scanner Specifications Switch Configurations Four-wire mode (any configuration) Two-wire mode (any configuration) Maximum Switchable Voltage 250 VDC, 250 VAC RMS (Terminal-Terminal or Terminal-Chassis) Maximum Switchable Current 1A, DC or AC RMS (Per Channel) Maximum Switchable Power 30 WDC, 62.5 VA AC (Per Channel)
Page 20
1260-37 User Manual 40 Channel SPDT Switch Maximum Switchable Voltage 250 VDC, 250 VAC RMS (Terminal-Terminal or Terminal Chassis) Maximum Switchable Current 1 A,DC or AC RMS (Per Channel) Maximum Switchable Power 30 WDC, 62.5 VA AC (Per Channel) <0.5 Ω Path Resistance Ω...
1260-37 User Manual *A crimp connector kit is also available for this module (P/N 404975-003). A strain relief option can be ordered separately for this crimp connector kit. Ordering Information Model Number Description Part Number 1260-37 1 x 48 Signal Multiplexer/ 407353 Scanner, 40-Channel, SPDT Switch...
1260-37 User Manual Chapter 2 INSTALLATION INSTRUCTIONS 1. Remove the 1260-37 module and inspect it for damage. If any Unpacking and damage is apparent, inform the carrier immediately. Retain Inspection shipping carton and packing material for the carrier’s inspection. 2. Verify that the pieces in the package you received contain the correct 1260-37 module option and the 1260-37 Users Manual.
1260-37 User Manual Installation of the 1260-37 Switching Module into a VXIbus Module mainframe, including the setting of DIP switches, is described in Installation the Installation Section of the 1260 Series VXIbus Switching Cards Manual. Configuration of the motherboard PCB and setting DIP switches S1-5 and S1-6 are described in the following sections.
1260-37 User Manual Table 2-1, 1260-37 Multiplexer/Scanner Circuit Jumper Installation An X indicates a jumper is to be installed. An (X) indicates the jumper is optional, depending on whether access to the analog bus is required. A blank indicates no jumper is to be installed. 8(1X6) 4(1X6) 4(1x12)
1260-37 User Manual Chapter 3 MODULE SPECIFIC SYNTAX Module Specific Syntax 1260-37 Signal 1260-37 Module Multiplexer/SPDT Switch is required in the use of the OPEN and Specific Syntax CLOSE commands. It will also appear in data output by the Master in response to the PDATAOUT and PSETUP commands.
1260-37 User Manual Note that the SPDT circuit channel number is preceded by a “1” to distinguish it from the Multiplexer/Scanner circuit. For the SPDT circuit, Channels 00 to 39 correspond to channels 100 to 139 in the command syntax. The actual mapping of channel number to connector pins for the Scanner/Multiplexer circuit is given in Table 3-1, and for the SPDT circuit in Figure 3-2.
1260-37 User Manual The response to the PSETUP command consists of a header on the first line. The header describes the model number, followed by a four-wire or two-wire to indicate the module setup. The next line designates the setup mode for scanning which, by default, is Break-Before-Make (BBM).
1260-37 User Manual The common output of channel 48 is the single channel of the 96 x I multiplexer, and the 48 HI and 48 LO connections make up the 96 channels. By closing the appropriate channel (0-47) and opening or closing channel 48, a 96 x I multiplexer is achieved.
Each harness documentation consists of an assembly drawing, parts list, system wire list and wire list. 407437 Virginia Panel, Inc. Series VP90 Interface Harness 407438 TTI Testron, Inc. Interface Harness For more information on Racal Instruments complete line of Test Receivers Interface solution, contact your Sales Representative.
1260-37 User Manual Chapter 5 PRODUCT SUPPORT Product Support EADS North America Defense Test and Services, Inc. has a complete Service and Parts Department. If you need technical assistance or should it be necessary to return your product for repair or calibration, call 1-800-722-3262. If parts are required to repair the product at your facility, call 1-949-859-8999 and ask for the Parts Department.
Page 59
1260-37 User Manual REPAIR AND CALIBRATION REQUEST FORM To allow us to better understand your repair requests, we suggest you use the following outline when calling and include a copy with your instrument to be sent to the EADS North America Defense Test and Service, Inc.
Need help?
Do you have a question about the 1260-37A and is the answer not in the manual?
Questions and answers