Pcie Gen 4 Nvme Enablement Kit - Dell EMC PowerEdge R6525 Installation And Service Manual

Hide thumbs Also See for EMC PowerEdge R6525:
Table of Contents

Advertisement

Figure 138. Installing the BOSS blank
To install the BOSS S2 controller card module:
1. Install the BOSS S2 controller card module. To install the BOSS S2 controller card module, see
controller card module
2. Install the M.2 SSD. To install the M.2 SSD, see
NOTE:
Installing the BOSS S2 card carrier does not require the system to be powered off. System shutdown is only
required when installing the BOSS S2 controller card module.
NOTE:
Connect the BOSS signal cable and BOSS power cable after inserting the BOSS S2 controller card module into the
system.
To remove the BOSS S2 controller card module:
1. Remove the M.2 SSD. To remove the M.2 SSD, see
2. Remove the BOSS S2 controller card module. To remove the BOSS S2 controller card module, see
controller card module
3. Install the BOSS blank.
NOTE:
Removal of the BOSS S2 card carrier does not require the system to be powered off. System shutdown is only
required when removing the BOSS S2 controller card module.
NOTE:
Disconnect the BOSS signal cable and the BOSS power cable before lifting the controller card module from the
system.

PCIe Gen 4 NVMe enablement Kit

NOTE:
To enable the PCIe Gen4 NVMe feature, update the BIOS version to 1.2.11 or greater and backplane firmware
version to be greater than 2.84. For latest firmware, refer to the System's Drivers and Downloads page at
support/drives
and search for PowerEdge R6525.
steps 1 to 3.
step 5 to 6.
installing the BOSS S2 controller card module
removing the BOSS S2 controller card module
installing the BOSS S2
steps 4 to 8.
step 1 to 4.
removing the BOSS S2