13. If the hotbox is not correctly
aligned, release the tension on the
Side entry
Rear entry
cables by slackening the screws and
turning the hexagonal adjusters fully
anticlockwise. The hotbox should then
automatically realign itself. Pull each
cable taut again and push the cable
retainers back against the back panel /
side panel. Again, tighten the screws
in the retainers and apply tension to
the cables by turning the hexagonal
adjusters clockwise as far as possible.
14.
Feed the free length of the cables
into the gap between the inner and
outer back panels so that they are
available to allow easy removal and
refitting of the appliance during
subsequent service calls. Do not cut
off the free lengths of cable. On
precast flue installations feed the
cables into the small holes at the base
of the side panels (See figure 23).
9.3 Sealing floor front - All
installations.
Using the floor sealing tape supplied,
Figure 23. Lower cable retention
seal the bottom of the hotbox to the
fireplace and hearth floor (See figure
24).
Make sure that the whole length of the front
edge of the hotbox is fully sealed.
Figure 24. Floor sealing