INSTALLER GUIDE
Figure 6. Pack contents

5. FIREPLACE CHECK

5.1 Fireplace check.
5.1.1 Fireplace size
The fireplace must comply with the requirements described in section 3.2. This will
probably entail removing the fireback and infill material behind the fireback. On
conventional fireplace openings the debris catchment area shown in figure 7 must be
kept clear of obstructions.
5.1.2 Fireplace general condition
The fireplace floor should be reasonably flat to ensure that the hotbox can be installed
without it rocking and so that a good seal can be made at the bottom front of the box.
The front face of the fireplace should be reasonably flat over the area covered by the
hotbox top and side flange seals to ensure good sealing. These faces should be made