INSTALLER GUIDE
4. Remove the hotbox. Drill four holes in the
fireplace front surround at the marked
positions using a no.12 masonry drill.
5. Insert a fibre plug into each hole.
6. Place the hotbox back in position in the
fireplace.
7. Fit a woodscrew through each hole in the
hotbox flanges and tighten to seal the box to
the fireplace surround.
9.2 Method 2 - Cable retention and floor
fixing.
1. Make sure that the relevant areas at the
Figure 18. Front Fixing
fireplace back and floor are
sound enough to take the
eyebolts and screws. If these
areas have deteriorated due to
prolonged use they should be
made sound with a suitable
cement.
2. Drill four holes in the rear
wall of the fireplace for the
eyebolt plugs. The holes
should be drilled within the
range of positions shown in
figure 19 using a no.12
masonry drill. The holes
should be equidistant each side
of the centre line of the
fireplace to ensure that the
appliance finishes centrally in
the opening when tension is
applied to the cables.
3. Insert a fibre plug into each
hole. Use the fibre plugs
supplied with this appliance -
Figure 19. Eyebolt positions
Never use plastic plugs
instead of the fibre plugs
supplied. Screw the eyebolts into the plugs. Make sure that the bolts are secure.
4. Place the hotbox unit close to the fireplace but allow sufficient access into the
fireplace opening so that the cables can be threaded through the eyebolts and returned
Page 19