6.2
baffl e installation
WARNING
!
Operation of the appliance without the baffl es can result in excessive temperatures that could damage the
appliance, chimney and the surrounding enclosure.
During shipping, the catalyst may have shifted from its proper location. Prior to initial burn, ensure the catalyst is
correctly installed. Refer to the "catalyst inspection and replacement" section.
CATALYST SHIELD
CERAMIC FIBRE
BAFFLE
SECONDARY AIR
TUBES
The NZ3000H-1 contains a ceramic fi bre baffl e, catalyst and catalyst shield. It is important that each of these
components are installed correctly prior to operating the appliance.
To install the ceramic baffl e, insert it through the front of the appliance and rest it on top of the secondary tubes as
far back as possible ensuring proper orientation as shown.
To install the catalyst, refer to the "catalyst inspection and replacement" section in this manual.
CATALYST
ANDIRON
fi nishing