Napoleon Ascent 36-1 Installation And Operation Manual

Napoleon Ascent 36-1 Installation And Operation Manual

Hide thumbs Also See for Ascent 36-1:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

NATURAL GAS MODELS:
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
$10.00
B36NTR-1 / B36NTRE-1
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
B36PTR-1 / B36PTRE-1
Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com
INSTALLATION AND
ADD MANUAL TITLE
OPERATION MANUAL
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
IF INSTALLATION + OPERATION, ADD SERIAL
CSA /
INTERTEK
BARCODE LABEL ON THE OWNER'S MANUAL"
LOGO
Ascent™ 36-1
Product Name / Code
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
NUMBER LABEL HERE
IF SEPARATE MANUALS, ADD "PLACE
ENGLISH
FRENCH PG. 75
W415-2835 / 01.16.20

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon Ascent 36-1

  • Page 1 IF SEPARATE MANUALS, ADD “PLACE INTERTEK BARCODE LABEL ON THE OWNER’S MANUAL” LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com $10.00 W415-2835 / 01.16.20...
  • Page 2 safety information WARNING • This appliance is hot when operated and DANGER can cause severe burns if contacted. • Any changes or alterations to this appliance or its controls can be dangerous and is prohibited. HOT GLASS WILL CAUSE • Do not operate appliance before reading and BURNS.
  • Page 3 safety information WARNING • Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this appliance. • This appliance must not be connected to a chimney fl ue pipe serving a separate solid fuel burning appliance.
  • Page 4: Table Of Contents

    table of contents general information electrical information rates and effi ciencies electronic wiring diagram installation overview battery back-up installation rating plate information gas installation mobile home installation operation (electronic) dimensions pilot-on-demand venting requirements operation (millivolt) typical vent installation finish framing special vent installations minimum framing dimensions 2.2.1 periscope termination...
  • Page 5: General Information

    standard checklist Installer, please fi ll out the following information: Customer: Address: Date of Installation: Location of appliance: Installer: Dealer/Distributor contact number: Serial #: Model: Natural Gas: B36NTR-1 Propane: B36PTR-1 B36NTRE-1 B36PTRE-1 B36NTR-PBR-1 B36PTR-PBR-1 1.0 general information When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations from the local authority having jurisdiction, the certifi...
  • Page 6: Installation Overview

    standard checklist installation overview Recommended installation steps: 1. Determine venting requirements before deciding the fi nal location of the appliance. 2. Install rough framing (see “rough framing” section). 3. Place the appliance in its fi nal position. 4. Install appliance venting (see “venting installation” section). 5.
  • Page 7 general information WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door opened or removed. • Provide adequate clearance for servicing and operating the appliance. • Provide adequate ventilation.
  • Page 8: Rating Plate Information

    Côtés et dessous du conduit d’évent X” the vent-air intake system. Recessed depth X” Profondeur d’encastré une face X” L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au *** Mantel X” from appliance opening opening ening *** Tablette X”...
  • Page 9 general information dimensions W415-2835 / 01.16.20...
  • Page 10 2.0 venting requirements venting requirements WARNING • Risk of fi re. Maintain specifi ed air space clearances to vent pipe and appliance. • The vent system must be supported every 3’(0.9m) for both vertical and horizontal runs. Use support ring assembly W010- 0067 or equivalent non-combustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs.
  • Page 11: Venting Requirements

    venting requirements A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. Local codes or regulations may require different clearances. Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1¼” (31.8mm) air gap all around between the inner liner and outer liner is required for safe operation.
  • Page 12 venting requirements 16" (40.6cm) minimum 40 ft (12m) maximum 3 ft (1m) minimum 20" (50.8cm) 24" (61cm) 24" minimum plus rise * (61cm) REAR VENT * See "venting" section W415-2835 / 01.16.20...
  • Page 13: Special Vent Installations

    venting requirements special vent installations 2.2.1 periscope termination Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” (305mm) above grade. The maximum allowable vent length (including both rise and run) is 10’...
  • Page 14: Minimum Air Terminal Location

    venting requirements minimum air terminal location clearances Covered balcony applications ††* = 3 feet = 2 x ACTUAL (4.6m) (0.9m) note: INSTALLATIONS Wall terminals are for illustration purposes only. Size and shapes may vary. CANADA U.S.A. 12” (30.5cm) 12” (30.5cm) Clearance above grade, veranda porch, deck or balcony.
  • Page 15: Venting Application Fl Ow Chart

    venting requirements venting application fl ow chart TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run...
  • Page 16: Defi Nitions

    venting requirements defi nitions For the following symbols used in the venting calculations and examples are: > - greater than > - equal to or greater than < - less than < - equal to or less than - total of both horizontal vent lengths (Hr) and offsets (Ho) in feet - combined horizontal vent lengths in feet - offset factor: .03 (total degrees of offset - 90°*) in feet - combined vertical vent lengths in feet...
  • Page 17: Top Exit Horizontal Termination

    venting requirements top exit horizontal termination ) < (V See graph to determine the required vertical Simple venting confi guration (only one 90° elbow) rise V for the required horizontal run H 40 (12.2) 40 (12.2) 39 (11.9) 39 (11.9) REQUIRED 30 (9.1) REQUIRED...
  • Page 18 venting requirements ) > (V Simple venting configuration See graph to determine the required vertical rise V for the required horizontal run H (only one 90° elbow) 150 (381) 147 (373) REQUIRED VERTICAL 100 (254) RISE IN INCHES (CENTIMETERS) V 57 (145) 50 (127) 8 (20.3)
  • Page 19: Rear Exit Horizontal Termination

    venting requirements rear exit horizontal termination ) < (V Simple venting configuration See graph to determine the required vertical rise V for the required (only two 90° elbows) horizontal run H 40 (12.2) 35.3 (10.7) REQUIRED 30 (9.1) VERTICAL RISE IN 20 (6.1) FEET (METERS) V...
  • Page 20 venting requirements ) > (V Simple venting configuration See graph to determine the required vertical rise V for the (only two 90° elbows) required horizontal run H 12.5 (3.8) 12.25 (3.7) REQUIRED VERTICAL RISE IN 8.3 (2.54) FEET (METERS)V (1.68) 4.2 (1.3) (0.3) 12.5...
  • Page 21: Top And Rear Exit Vertical Termination

    venting requirements top and rear exit vertical termination ) < (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H 40 (12.2) 30 (9.1) REQUIRED VERTICAL RISE IN FEET 20 (6.1) (METERS)V 10 (3.1) 3 (0.9)
  • Page 22 venting requirements ) > (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H 20 (6.1) 19 (5.8) REQUIRED VERTICAL 10 (3.1) RISE IN FEET 3 (0.9) (METERS)V (1.5) (3.1) (4.6) (6.1) (7.6) (9.1)
  • Page 23: Rear Exit

    venting requirements Example: = 1.5 FT (0.5m) = 5 FT (1.5m) = 1.5FT (0.5m)+ 5FT (1.5m) = 6.5 FT (2m) = 1 FT (0.3m) = 1 FT (0.3m) = 10.75 FT (3.3m) = 1FT (0.3m) + 1FT (0.3m) + 10.75FT (3.3m) = 12.75FT (3.9m) = .03 (three 90°...
  • Page 24: Rear Exit Shield (For Rear Vent Only)

    venting requirements 2.11 rear exit shield (for rear vent only) Remove the safety barrier assembly and door from the appliance (see “safety barrier & door removal / installation” section). Loosen the two screws that secure the exhaust plate, and slide the shield in place by sliding its slotted openings behind the screwheads.
  • Page 25: Top Exit

    venting requirements 2.12 top exit WARNING • Failure to install the cover plate and gasket will cause the appliance to function improperly and can cause injury or property damage. Remove the safety barrier and glass door (see "safety barrier & door removal/installation" section). Remove the contents from the fi...
  • Page 26 rough framing 3.0 rough framing note: When using optional fi nishing accessories, the framing dimensions and fi nishing materials may differ from what is outlined in the section below; refer to the leafl et instructions supplied in the accessory kit for specifi c framing and fi...
  • Page 27: Rough Framing

    rough framing minimum framing dimensions HORIZONTAL VENT SECTIONS: A minimum of 1" (25mm) at the bottom and sides, and 3" (76.2mm) at the top of the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-3440 (supplied). note: The minimum clearances from the top of the horizontal vent pipe to combustible materials may be reduced from 3"...
  • Page 28: Minimum Enclosure Clearances

    rough framing minimum enclosure clearances TOP VENT CEILING ENCLOSURE TOP EXIT ENCLOSURE The appliance requires a minimum enclosure height of 50 1/2" (128.3cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. note: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration. * See "minimum framing dimensions"...
  • Page 29 rough framing MINIMUM REAR VENT CLEARANCES For rear vent termination not exceeding 10" (254mm) of horizontal vent run. Ceiling Enclosure REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41" (104.1cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. note: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.
  • Page 30 rough framing MAXIMUM REAR VENT CLEARANCES (EXAMPLE 1: INTERIOR NICHE / BUMPOUT / ALCOVE) REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41" (104.1cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. note: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.
  • Page 31 rough framing MAXIMUM REAR VENT CLEARANCES (EXAMPLE 2: EXTERIOR ALCOVE / DOGHOUSE) REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41" (104.1cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. note: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.
  • Page 32 rough framing note: For heavier fi nishing materials such as marble, we recommend adding extra support to the frame. Ensure there is adequate fl oor support for the appliance and fi nishing material. Before framing your appliance, determine vent requirements before deciding the fi nal location of the appliance. After rough framing, place the appliance in its fi...
  • Page 33 4.0 venting installation venting installation WARNING • Ensure to unpack all loose materials from inside the fi rebox prior to connecting the gas and electrical supply • If your appliance is supplied with a remote, ensure the remote receiver is in the “OFF” position prior to connecting the gas and electrical supply to the appliance.
  • Page 34: Venting Installation

    venting installation horizontal installation WARNING • The fi restop assembly must be installed with the vent shield to the top. • Terminals must not be recessed into a wall or siding more than the depth of the return fl ange of the mounting plate.
  • Page 35: Using Either Fl Exible Or Rigid Vent

    venting installation using either fl exible or rigid vent components WARNING • Do not allow the inner fl ex pipe to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. • Spacers are attached to the inner fl ex pipe at predetermined intervals to maintain an even air gap to the outer fl...
  • Page 36: Vertical Air Terminal Installation

    venting installation 4.3.2 vertical air terminal installation WARNING • Maintain a minimum 2” (51mm) space between the air inlet base and the storm collar. note: Fastening hardware provided with appropriate roof terminal and liner kits. Fasten the roof support to the roof using 6 screws. The roof support is optional.
  • Page 37: Horizontal Air Terminal Installation

    venting installation 4.3.4 horizontal air terminal installation Move the appliance into position. Measure #10x2" the vent length required between terminal and SCREWS appliance taking into account the additional CAULKING length needed for the fi nished wall surface and any 2” (50.8mm) overlaps between venting INNER components.
  • Page 38: Vertical Air Terminal Installation

    venting installation 4.3.5 vertical air terminal installation WARNING • Maintain a minimum 2” (51mm) space between the air inlet base and the storm collar. note: Fastening hardware provided with appropriate roof terminal and liner kits. Before attaching elbows to the collars on the back of the appliance, 1 1/2” (38.1mm) will need to be trimmed off the 4”...
  • Page 39: Vertical Through Existing Chimney

    venting installation vertical through existing chimney WARNING • Risk of fi re. • Co-axial to co-linear venting confi gurations must only be used in a non-combustible chimney or enclosure. Installation in a combustible enclosure could result in a fi re. This appliance is designed to be attached to a 3”...
  • Page 40: Restricting Vertical Vents

    venting installation 4.4.1 restricting vertical vents WARNING • Turn off gas and electrical supply before servicing the appliance. • Appliance may be hot. Do not service until appliance is cool. • For safe and proper operation of the appliance, follow the venting instructions exactly. •...
  • Page 41: Electrical Information

    venting installation 5.0 electrical information electronic wiring diagram WARNING • Do not wire 110 volts to the valve or wall switch. (where applicable) GREEN ON / OFF ORANGE SWITCH TRANSFORMER IPI / CPI ON / OFF BATTERY HOUSING ELECTRONIC DISCONNECT THESE VALVE CONNECTIONS TO THE ON/OFF SWITCH.
  • Page 42: Battery Back-Up Installation

    electrical information battery back-up installation WARNING • Ensure the gas and electrical power to the appliance is turned off. • Appliance may be hot. Do not service until the appliance has cooled. note: In the event of a power failure, your appliance can be operated using the battery back-up supplied. Remove the safety barrier by lifting it up and off of the four shoulder screws.
  • Page 43: Gas Installation

    6.0 gas installation gas installation WARNING • Risk of fi re, explosion, or asphyxiation. Ensure there are no ignition sources such as sparks or open fl ames. • Support gas control when attaching gas supply pipe to prevent damaging gas line. •...
  • Page 44: Operation (Electronic)

    7.0 operation (electronic) operation (electronic) WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 45: Pilot-On-Demand

    In order to start your pilot, turning the main burner on with the switch, remote or thermostat and then turning it off will reactivate the continuous pilot mode and reset the seven day timer. For further information, refer to www.napoleon.com/pilotondemand. W415-2835 / 01.16.20...
  • Page 46: Operation (Millivolt)

    operation (electronic) 8.0 operation (millivolt) WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 47: Finish Framing

    9.0 fi nish framing fi nish framing minimum framing dimensions 35" 88.9cm 16" 40.6cm W415-2835 / 01.16.20...
  • Page 48: Finishing

    10.0 fi nishing fi nishing WARNING • Risk of fi re! • Never obstruct the front opening of the appliance. • The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite, etc., provided that these materials do not go below the specifi ed dimension, as illustrated. •...
  • Page 49: Front Hood Installation

    fi nishing 10.2 front hood installation note: This hood must be installed, if it has not already been factory installed. Safety door and barrier must be removed. Remove the securing screws from the top of the fi rebox, as shown. Install the front hood, ensuring it is angled downward when installed.
  • Page 50: Non-Combustible Facing Material

    fi nishing 10.3 non-combustible facing material WARNING Non-combustible facing material must not project more than 4” (101.6mm) from the face of the door (all four sides). If greater projections are desired, increase the clearance to the sides, bottom and top by 2” (50.8mm) for every additional 1”...
  • Page 51: Minimum Mantel Clearances

    fi nishing 10.4 minimum mantel clearances WARNING • Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructions may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel, front, etc.) are clearly maintained.
  • Page 52: Recessed Installation

    fi nishing 10.5 recessed installation WARNING • Installing a television or other electronics above the appliance may cause discolouration, melting, or damage to the electronics. Use clearances as guidelines and refer to your TV manufacturer’s instructions for further information Image note: Recesses or alcoves above the appliance must be made with non-combustible material and regular minimum clearances, as defi...
  • Page 53: Log Placement

    • The logs are fragile and should be handled with care. PHAZER™ logs and glowing embers, exclusive to Napoleon, provide a unique and realistic glowing effect that is If applicable, insert the following statement: different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect.
  • Page 54 fi nishing Holes under log (not illustrated). Holes under log (not illustrated). Notch Place the holes in log #1 on A1 and A2. Place the holes in log #2 on B1 and B2. Do not cover any burner ports. Ensure the notch fi ts around the pilot shield. Holes and notch Holes under log not illustrated.
  • Page 55 fi nishing note: When burning, a good indicator that logs are installed correctly is that each fl ame stands reasonably straight. If a log splits a fl ame or drastically changes the direction of a fl ame, review instructions again and/or pivot log out of direct contact.
  • Page 56: Glowing Embers

    fi nishing 10.7 glowing embers WARNING • Completely blocking the burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. Tear the embers into pieces and loosely layer above the burner ports covering the burner area. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi...
  • Page 57: Optional Blower Installation

    11.0 optional blower installation WARNING • Ensure the appliance is completely cool before starting installation. • To avoid danger of suffocation, keep the packaging bag away from babies and children. Do not use in cribs, beds, carriages, or play pens. This bag is not a toy. Knot before throwing away. 1.
  • Page 58: Adjustment

    adjustment 12.0 adjustment 12.1 pilot burner adjustment Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. ELECTRONIC 3/8” - 1/2” Check Pressure Readings: (9.5mm - 12.7mm) ILLUSTRATED Inlet pressure can be checked by turning screw (A) counter- Flame must envelop clockwise 2 or 3 turns and then placing pressure gauge tubing upper...
  • Page 59: Fl Ame Characteristics

    adjustment 12.3 fl ame characteristics 3/8” - 1/2” It’s important to periodically perform a visual check of (9.5mm - 12.7mm) the pilot and burner flames. Compare them to the ADD IMAGE illustration provided. If any flames appear abnormal, Flame must envelop call a service person.
  • Page 60: Maintenance

    13.0 maintenance maintenance WARNING • Turn off the gas and electrical power before servicing the appliance. • Appliance may be hot. Do not service until appliance has cooled. • Do not use abrasive cleaners on glass. • Do not paint the pilot assembly. This appliance and its venting system should be inspected before use and at least annually by a qualifi...
  • Page 61: Annual Maintenance

    maintenance 13.1 annual maintenance WARNING • Annual maintenance should be performed by a qualifi ed service technician • The fi rebox becomes very hot during operation. Let the appliance cool completely or wear heat resistant gloves before conducting service. • Never vacuum hot embers.
  • Page 62: Door Glass Replacement

    maintenance 13.2 door glass replacement WARNING • Do not use substitute materials. • Glass may be hot. Do not touch glass until cooled. • Care must be taken when removing and disposing of any broken door glass or damaged components. Be sure to vacuum up any broken glass from inside appliance before operation.
  • Page 63: Replacement Parts

    replacements 14.0 replacement parts WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 64: Overview

    replacement parts W415-2835 / 01.16.20...
  • Page 65: Millivolt Valve Train Assembly

    replacement parts W415-2835 / 01.16.20...
  • Page 66: Electronic Valve Train Assembly

    replacement parts W415-2835 / 01.16.20...
  • Page 67: Accessories

    15.0 accessories W415-2835 / 01.16.20...
  • Page 68: Troubleshooting (Electronic)

    16.0 troubleshooting (electronic) troubleshooting WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. •...
  • Page 69 troubleshooting (electronic) symptom problem test solution Pilot will not light. Makes Wiring: short, loose, or damaged Verify the thermocouple/sensor is clean and the wiring is undamaged. Verify the interrupter block is not damaged or too tight. Verify noise with no spark at connections connections from pilot assembly are tight;...
  • Page 70 troubleshooting (electronic) symptom problem test solution Lights or blower Control module switch in Verify ON/OFF switch is in the “I” position which denotes on. won’t function (if wrong position. equipped). COM switch is unplugged. Verify “COM” switch is plugged into the front of the control module.
  • Page 71: Troubleshooting (Millivolt)

    17.0 troubleshooting (millivolt) WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. •...
  • Page 72 troubleshooting (millivolt) symptom problem test solution Pilot will not light. No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button ignitor. Check if the push button ignitor needs tightening. 3/8”...
  • Page 73: Warranty

    Napoleon neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Napoleon will not be responsible for: over- fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi...
  • Page 74 NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Phone: 1-866-820-8686...
  • Page 75 IF SEPARATE MANUALS, ADD “PLACE LOGO BARCODE LABEL ON THE OWNER’S MANUAL” Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 1(866)820-8686 • www.napoleon.com • hearth@napoleon.com $10.00 W415-2835 / 01.16.20...
  • Page 76 consignes de sécurité AVERTISSEMENT • Cet appareil est chaud lorsqu’il AVERTISSEMENT fonctionne et peut causer de graves brûlures en cas de contact. • Toute modifi cation apportée à cet appareil ou aux contrôles peut être LA VITRE CHAUDE CAUSERA dangereux et est interdit. DES BRÛLURES.
  • Page 77 consignes de sécurité AVERTISSEMENT • N’utilisez pas une souffl erie intégrée, un échangeur de chaleur intégré ni un autre accessoire non approuvé pour cet appareil. • Cet appareil ne doit pas être raccordé au conduit d’une cheminée desservant un autre appareil de chauffage à...
  • Page 78 table des matières information électrique information générale schéma de câblage électronique taux et effi cacités vue d'ensemble d'installation installation du sauvegarde de pile information à propos de la plaque branchement du gaz d’homologation opération (électronique) installation dans une maison mobile veilleuse sur demande dimensions opération (millivolt)
  • Page 79: Information Générale

    liste de vérifi cation Installateur, veuillez rempli les informations suivants: Client: Adresse: Date d’installation: Location de l’appareil: Installateur: Numéro de contact du détaillant / distributeur: # de série: Modèle: Gaz Naturel: B36NTR Propane: B36PTR B36NTRE B36PTRE B36NTR-PBR-1 B36PTR-PBR-1 1.0 information générale Lorsque l’appareil est installé...
  • Page 80: Vue D'ensemble D'installation

    information générale vue d'ensemble d'installation Étapes d'installation recommandées: 1. Determinez les exigences d'évacuation avant de determinez le position fi nale de l'appareil. 2. Installez l'encadrement approximatif (voir la section « encadrement approximatif »). 3. Placez l'appareil dans le position fi nale. 4.
  • Page 81 information générale AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Prévoyez un accès suffi sant pour entretenir et opérer l’appareil. •...
  • Page 82: Information À Propos De La Plaque

    Recessed depth X” Recessed depth X” Profondeur d’encastré une face X” L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au *** Mantel X” from appliance opening ** Mantel X” from a ** Mantel X” from *** Tablette X”...
  • Page 83 information générale dimensions W415-2835 / 01.16.20...
  • Page 84 2.0 exigences d'évacuation exigences d'évacuation AVERTISSEMENT • Risque d’incendie. Conservez les dégagements nécessaires au conduit d’évent et à l’appareil. • Les courses horizontales et verticales du système doivent être supportées à tous les 3 pi (0,9m). Utilisez l’ensemble de support mural Wolf Steel W010-0067 ou des attaches incombustibles équivalents afi n de maintenir le dégagement aux matériaux combustibles pour les courses verticales et horizontales.
  • Page 85: Exigences D'évacuation

    exigences d'évacuation Ne combinez pas de composants rigides ou fl exibles ni de composants d’évacuation provenant de fabricants différents. Ces ensembles d’évents permettent soit une évacuation verticale, soit une évacuation horizontale de l’appareil. La course horizontale doit être conservée à un maximum de 20PI (6,1m). La hauteur totale permise pour un évent vertical est de 40PI (12,2m).
  • Page 86 exigences d'évacuation 16" (40,6cm) minimum 40 pi (12m) maximum 3 pi (1m) minimum 20" (50,8cm) 24" 24" (61cm) (61cm) plus la pente * ÉVACUATION SUR L'ARRIÈRE * Voir la section « évacuation » W415-2835 / 01.16.20...
  • Page 87: Installations Particulières D'évents

    exigences d'évacuation installations particulières d'évents 2.2.1 ensemble périscopique Utilisez l’ensemble périscopique afi n de positionner la terminaison au-dessus du niveau du sol. L’ensemble périscopique doit être installé de façon à ce que la fente d’air du bas soit située à un minimum de 12 pouces (305mm) au-dessus du niveau du sol.
  • Page 88: Emplacements Et Dégagements Minimaux De La Terminaison

    exigences d'évacuation emplacements et dégagements minimaux de la terminaison Applications pour balcon couvert ††* = 3 feet = 2 x ACTUAL (4.6m) (0.9m) note: INSTALLATIONS Les terminaux du mur sont à des fi ns d’illustration seulement. La taille et les formes peuvent varier. CANADA É.-U.
  • Page 89: Charte D'application Des Évacuations

    exigences d'évacuation charte d'application des évacuations ÉVACUATION SUR LE DESSUS Terminaison horizontale Terminaison verticale La course verticale La course verticale La course verticale est La course verticale est est plus petite que la plus grande ou égale à est plus petite que la plus grande ou égale à...
  • Page 90: Valeurs Du Coude En Longueurs D'évent

    exigences d'évacuation valeurs du coude en longueurs d'évent PIEDS POUCES MILLIMÈTRES 1° 0,03 12,7 15° 0,45 152,4 30° 11,0 279,4 45° 1,35 16,0 406,4 90°* 32,0 812,8 * La première déviation de 90° a une valeur zéro et est illustrée dans la formule comme - 90° évacuation sur le dessus terminaison horizontale ) <...
  • Page 91 exigences d'évacuation ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H (un coude de 90° seulement) 150 (381) 147 (373) COURSE VERTICALE 100 (254) REQUISE EN POUCES (CENTIMÈTRES)V 57 (145)
  • Page 92: Évacuation Sur L'arriére Terminaison Horizontale

    exigences d'évacuation évacuation sur l'arriére terminaison horizontale ) < (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire (deux coudes de 90° seulement) par rapport à la course horizontale requise H 40 (12,2) 38,3 (11,7) COURSE 30 (9,1) VERTICALE REQUISE...
  • Page 93 exigences d'évacuation ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale (deux coudes de 90° seulement) nécessaire V par rapport à la course horizontale requise H 12,5 (3,8) 12,25 (3,7) COURSE VERTICALE 8,3 (2,54) REQUISE EN PIEDS (MÈTRES) V (1,68)
  • Page 94: Terminaison Verticale

    exigences d'évacuation évacuation sur l'arriére et au dessus terminaison verticale ) < (V Consultez le graphique pour déterminer la course verticale Configurations d'évacuation simples. nécessaire V par rapport à la course horizontale requise H 40 (12,2) 30 (9,1) COURSE VERTICALE 20 (6,1) REQUISE EN PIEDS...
  • Page 95 exigences d'évacuation ) > (V Configurations d'évacuation simples. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 20 (6,1) 19 (5,8) COURSE VERTICALE REQUISE EN 10 (3,1) PIEDS (MÈTRES) V 3 (0,9) (1,5) (3,1) (4,6)
  • Page 96: Évacuation À L'arrière

    exigences d'évacuation 2.10 évacuation à l'arrière AVERTISSEMENT • Il est essentiel que le couvercle d'évacuation soit installé. si non, l'appareil ne fonctionnera pas correcte- ment et pourrait causer des blessures ou des dommages matériels. Enlevez l'écran de protection et vitre de la porte (voir la section «...
  • Page 97: Défl Ecteur Du Ventilation Arrière

    exigences d'évacuation 2.11 défl ecteur du ventilation arrière (pour l'application de ventilation arrière) Retirez l'assemblage de l'écran de protection et la porte de l'appareil (voir la section « installation et enlevement de l'écran de protection et la porte »). Desserrez les deux vis servant à fi xer la plaque d'évacuation, installez le défl ecteur en glissant les ouvertures en forme de fentes derrière les têtes de vis, puis resserrez les vis (Fig.
  • Page 98: Évacuation Sur Le Dessus

    exigences d'évacuation 2.12 évacuation sur le dessus AVERTISSEMENT • Il est essentiel que le couvercle d'évacuation soit installé, si non, l'appareil ne fonctionnera pas correcte- ment et pourrait causer des blessures ou des dommages matériels. Enlevez l'écran de protection et vitre de la porte (voir la section « installation et enlevement de l'écran de protection et la porte »).
  • Page 99: Encadrement Approximatif

    encadrement approximatif 3.0 encadrement approximatif note: Lorsque vous installez les accessoires de fi nition optionelles, les dimensions de l’ossature et les matériaux de fi nition peuvent différer de ce qui est décrit dans ces instructions ci-dessous, voir les instructions fournies dans le trousse de l’accessoire pour les spécifi...
  • Page 100: Dégagements Minimaux De L'ossature

    encadrement approximatif dégagements minimaux de l'ossature SECTIONS D’ÉVENTS HORIZONTALES: Un dégagement minimal aux matériaux combustibles de 1" (25mm) au-dessous et sur les côtés de l’évent et de 3" (76,2mm) au-dessus doit être maintenu sur toutes les courses horizontales. Utilisez l’espaceur coupe-feu W010-3440 (fourni). note: Les dégagements minimaux entre le haut de l’évent et les matériaux combustibles peut être réduite de 3"...
  • Page 101: Dégagements Minimaux De L'enceinte

    encadrement approximatif dégagements minimaux de l'enceinte ÉVACUATION SUR LE DESSUS PLAFOND ENCEINTE ENCEINTE AVEC ÉVACUATION SUR LE DESSUS L'enceinte de l'appareil doit avoir une hauteur minimale de 50 1/2" (128,3cm). Afi n de respecter les contraintes de température, l’espace à l’intérieur de l’enceinte, autour de l'appareil et au-dessus, doit demeurer sans obstruction. note: L'écran de protection est télescopique et doivent être ajusté...
  • Page 102 encadrement approximatif ÉVACUATION À L'ARRIÈRE Pour la ventilation arrière ne dépassement pas 10" (254mm) de section horizontale de ventilation. Plafond Enceinte ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 41" (104,1cm). Afi n de respecter les contraintes de température, l’espace à...
  • Page 103 encadrement approximatif DÉGAGEMENTS MAXIMAUX D'ÉVACUATION À L'ARRIÈRE (EXEMPLE 1: NICHE / BUMPOUT / ALCÔVE INTÉRIEUR) ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 41" (104,1cm). Afi n de respecter les contraintes de température, l’espace à l’intérieur de l’enceinte, autour de l'appareil et au-dessus, doit demeurer sans obstruction.
  • Page 104 encadrement approximatif DÉGAGEMENTS MAXIMAUX D'ÉVACUATION À L'ARRIÈRE (EXEMPLE 2: ALCÔVE / NICHE EXTÉRIEUR) ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 41" (104,1cm). Afi n de respecter les contraintes de température, l’espace à l’intérieur de l’enceinte, autour de l'appareil et au-dessus, doit demeurer sans obstruction.
  • Page 105 encadrement approximatif note: Pour les matériaux de fi nition plus lourds comme du marbre, nous vous recommandons d’ajouter un support additionnel à l’ossature. Assurez-vous que le support de plancher est adéquat pour l’appareil et le matériau de fi ntion. Avant d’encadrer votre appareil, déterminez les exigences de ventilation avant de décider de l’emplacement fi nale de l’appareil.
  • Page 106: Installation D'évacuation

    installation d'évacuation 4.0 installation d'évacuation AVERTISSEMENT • Avant d’effectuer les branchements pour l’alimentation en gaz et électronique, assurez-vous de retirer toute composante non fi xée à l’intérieur de la chambre de combustion. • Si votre appareil comprend un système de télécommande, assurez-vous que le récepteur est à la position «...
  • Page 107: Installation Horizontale

    installation d'évacuation installation horizontale AVERTISSEMENT • L’espaceur coupe-feu doit être installé avec l’écran protecteur orienté vers le haut. • La terminaison ne doit pas être enchâssée dans le mur ou le revêtement extérieur plus que l’épaisseur de la bride de la plaque de montage. Cette confi...
  • Page 108: Installation Verticale

    installation d'évacuation installation verticale Cette confi guration s’applique lorsque l’évacuation se fait à travers un toit. Des ensembles d’installation pour les différentes pentes de toit sont disponibles chez votre détaillant autorisé. Voir la section « accessoires » dans le manuel du propriétairepour commander l’ensemble spécifi que dont vous avez besoin.
  • Page 109: Installation De La Terminaison

    installation d'évacuation 4.3.1 installation de la terminaison horizontale Étirez la gaine fl exible intérieure à la longueur requise en tenant compte de la longueur additionnelle nécessaire ADD FASTENER TYPE pour la surface du mur fi ni. Appliquez un généreux joint de scellant à haute température Mill Pac (W573- 0007) (non fourni).
  • Page 110: Installation De La Terminaison Verticale

    installation d'évacuation 4.3.2 installation de la terminaison verticale AVERTISSEMENT • Conservez un espace minimale de 2 po (51mm) entre la base de la prise d’air et le collet de solin. Matériel de fi xation fourni avec les ensembles de terminal pour toit et raccord appropriées. Fixez le support de toit au toit à...
  • Page 111: Installation De La Terminaison

    installation d'évacuation 4.3.4 installation de la terminaison horizontale Mettez l’appareil en place. Mesurez la longueur #10x2" d’évent requise entre la terminaison et l’appareil en tenant compte de la longueur additionnelle CALFEUTRAGE nécessaire pour la surface du mur fi ni et tout chevauchement de 2”...
  • Page 112: Installation De La Terminaison Verticale

    installation d'évacuation 4.3.5 installation de la terminaison verticale AVERTISSEMENT • Conserves un espace minimal de 2” (51mm) entre la base de la prise d’air et le collet de solin. note: Avant de fi xer les coudes aux collets à l’arriére de l’appareil, enlevez 1 1/2” (38.1mm) au collet de 4” (101.6mm) Matériel de fi...
  • Page 113: Terminaison Verticale À Travers Une Cheminée Existante

    installation d'évacuation terminaison verticale à travers une cheminée existante AVERTISSEMENT • Risque d’incendie • Les confi gurations d’évacuation coaxiales à colinéaires ne doivent être utilisées que dans une cheminée ou une enceinte de nature incombustible. Une installation dans une enceinte combustible peut causer un incendie. Cet appareil est conçu pour être raccordé...
  • Page 114: Renstreignant Des Évents Verticaux

    installation d'évacuation 4.4.1 renstreignant des évents verticaux AVERTISSEMENT • Mettez hors tension de gaz et de l'alimentation électrique avant d'intervenir sur l'appareil. • L'appareil peut être chaud, pas de service jusqu'à ce que l'appareil est refroidi. • Pour l'utilisation sure et correcte de l'appareil, suivez les instructions d'évacuation exactement. •...
  • Page 115: Information Électrique

    5.0 information électrique information électrique schéma de câblage électronique AVERTISSEMENT • Ne raccordez pas l’interrupteur mural ou la soupape de gaz à l’alimentation électrique (110 volts). (où applicable) INTERRUPTEUR VERT ORANGE MARCHE/ARRÊT TRANSFORMATEUR IPI / CPI* ON / OFF BOÎTIER DÉBRANCHEZ CES DE PILES RACCORDS DE L’INTERRUP-...
  • Page 116: Installation Du Sauvegarde De Pile

    information électrique installation du sauvegarde de pile AVERTISSEMENT • Assurez-vous que le gaz et l'alimentation électrique de l'appareil sont éteints. • L'appareil peut être chaud. Ne pas entretenir avant que l'appareil ne soit refroidi. note: En cas d'une panne de courant, votre appareil peut fonctionner utilisant le sauvegarde de pile fourni. Enlevez l’écran de protection en le levant vers le haut hors des quatre vis d’épaulement.
  • Page 117: Branchement Du Gaz

    6.0 branchement du gaz branchement de gaz AVERTISSEMENT • Risque d’incendie, d’explosion, ou d’asphyxie. Assurez-vous qu’il n’y ait aucune source d’allumage comme des étincelles ou une fl amme nue. • Soutenez le contrôle du gaz lorsque vous attachez le tuyau pour éviter de plier la conduite de gaz. •...
  • Page 118: Opération (Électronique)

    opération (électronique) 7.0 opération (électronique) AVERTISSEMENT • Si ces instructions ne sont pas suivies à la lettre, un incendie ou une explosion pourraient s’ensuivre, causant des dommages matériels, des blessures corporelles ou des pertes de vie. • Si applicable, allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée.
  • Page 119: Veilleuse Sur Demande

    Pour démarrer la veilleuse, en allumant le brûleur principal à l’aide de l’interrupteur, de la télécommande ou du thermostat, et ensuite en l’éteignant, réactivera le mode veilleuse permanente et réinitialisera la minuterie de sept jours. Pour plus d’informations, consultez le site www.napoleon.com/pilotondemand. W415-2835 / 01.16.20...
  • Page 120: Opération (Millivolt)

    opération (électronique) 8.0 opération (millivolt) AVERTISSEMENT • Si ces instructions ne sont pas suivies à la lettre, un incendie ou une explosion pourraient s’ensuivre, causant des dommages matériels, des blessures corporelles ou des pertes de vie. • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée Assurez-vous que l’arrivée de gaz au brûleur est continue avant de réinstaller la porte.
  • Page 121: Encadrement Fini

    9.0 encadrement fi ni encadrement fi ni dimensions minimaux de l'ossature 35" 88,9cm 16" 40,6cm W415-2835 / 01.16.20...
  • Page 122: Finitions

    fi nitions 10.0 fi nitions AVERTISSEMENT • Risque d'incendie! • N'obstruez jamais l'ouverture sur le devant de l'appareil. • La fi nition de la façade doit être fait avec de matériau incombustible comme de la brique, du marbre du granite, etc., sous réserve que ces matériaux ne dépassent pas le dimension spécifi...
  • Page 123: Installation De L'hotte Avant

    fi nitions 10.2 installation de l'hotte avant note: Cette hotte doit être installé si elle n’a pas déjà été installée en usine. La porte et l'écran de protection doivent être enlèvés. Retirez les vis de fi xation de la partie supérieure de l'appareil, comme illustré. Installez l'avant hotte, assurer qu'elle est inclinée vers le bas lorsqu'il est installé.
  • Page 124: Matériau De Fi Nition Incombustible

    fi nitions 10.3 matériau de fi nition incombustible AVERTISSEMENT Les matériaux de finition incombustibles ne doivent pas dépasser de plus 4” (101,6mm) la façade de la porte (sur toutes côtés). Si des projections plus grandes sont requises, augmentez les dégagements des côtés et du dessus de 2"...
  • Page 125: Dégagements Minimaux De La Tablette

    fi nitions 10.4 dégagements minimaux de la tablette AVERTISSEMENT • Rique d’incendie. Conservez tous les dégagements aux matériaux combustibles spécifi és. Incapacité de se conformer à ces instructions peut causer un incendie ou une surchauffe. Assurez-vous que tous les dégagements (arrière, côtés, dessus, évents, tablette, façade, etc.) sont respectés à la lettre. •...
  • Page 126: Installation Encadrée

    fi nitions 10.5 installation encadrée AVERTISSEMENT • Installation d’une télévision ou d’autres appareils électroniques au-dessus de l’appareil peut provoquer une décoloration, la fonte, détérioration ou des autres dommages aux composants électroniques. Utiliser les autorisations que les lignes directrices et référer aux instructions qui se trouvent dans le manuel d’installation du fabricant de votre électroniques.
  • Page 127: Disposition Des Bûches

    fi nitions 10.6 disposition des bûches AVERTISSEMENT • Omettre de positionner les bûches conformément aux schémas ou omettre d’utiliser uniquement des bûches spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. • Les bûches doivent être placées correctement à l’intérieur de l’appareil. Ne changez pas la position des bûches car l’appareil risque de ne pas fonctionner adéquatement et un retard d’allumage risque de se produire.
  • Page 128 fi nitions Trous au des- sous de bûche Trous au des- (non illustrés). sous de bûche Encoche (non illustrés). Placez les trous dans bûche n° 1 sur A1 et A2. Placez les trous dans bûche n° 2 sur B1 et B2. Ne couvrez pas les orifi...
  • Page 129 fi nitions note: En brûlant, un bon indicateur que les bûches sont installés correctement est que chaque fl amme se tient raison- nablement droite. Si une bûche fend une fl amme ou si c’elle change radicalement la direction de la fl amme, examinez les instructions encore et/ou pivotez la bûche hors de contact direct.
  • Page 130: Braises Incandescentes

    fi nitions 10.7 braises incandescentes AVERTISSEMENT • Obstruez pas ni fermer les orifi ces du brûleur. Le blocage des orifi ces du brûleur peut créer une fl amme irrégulière, des dépôts de carbone et un retard d’allumage. Déchirez les braises incandescentes en morceaux et placez une couche lâche sur le grillage du brûleur. Les braises devraient être déchirées très soigneusement en petits morceaux minces irréguliers, car seuls les côtés des fi...
  • Page 131: Installation De La Soufflerie Optionnelle

    11.0 installation de la souffl erie optionnelle AVERTISSEMENT • Assurez-vous que l'appareil est complètement refroidi avant de commencer l'installation. • Afi n d'éviter les risques de suffocation, gardez le sac d'emballage loin des bébés et des jeunes enfants. Ne le laissez pas traîner dans les berceaux, les lits, les pousettes, ou les parcs de jeu. Ce sac n'est pas un jouet. Nouez-le avant de le jeter.
  • Page 132: Réglages

    12.0 réglages 12.1 réglage de la veilleuse Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. Tournez vers la droite pour réduire l’apport de gaz. 3/8” - 1/2” ÉLECTRONIQUE (9.5mm - 12.7mm) Vérifi ez la pression: ILLUSTRÉ...
  • Page 133: Réglage Du Venturi

    12.2 réglage du venturi L’ouverture du volet d’air a été préréglée en usine selon le tableau ci-dessous: Indépendamment de l’orientation du venturi, plus le volet est fermé, plus la VENTURI flamme est jaune et aura tendance à causer des dépôts de carbone. Plus le volet est ouvert, plus la flamme est bleue et plus elle a tendance à...
  • Page 134: Entretien

    entretien 13.0 entretien AVERTISSEMENT • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. • L’appareil peut être chaud. Attendez qu’il soit refroidi avant d’en faire l’entretien. • N’utilisez pas de produits abrasifs. • Ne peinture pas l’assemblage de la veilleuse. Cet appareil et son système d’évacuation devraient être inspectés avant la première utilisation et au moins une fois l’an par un technicien de service qualifi...
  • Page 135: Entretien Annuel

    entretien 13.1 entretien annuel AVERTISSEMENT • Le caisson devient trés chaud lors du fonctionnement. Laissez l’appareil se refroidir complétement ou portez des gants antichaleur avant d’effectuer l’entretien. • Ne jamais aspirer des braises qui sont chaudes. • Ne peinturez pas l’assemblage de la veilleuse. •...
  • Page 136: Remplacement De La Vitre De Porte

    entretien 13.2 remplacement de la vitre de porte AVERTISSEMENT • N’utilisez pas de matériaux de substitution. • La vitre peut étre chaude, ne touchez pas la vitre jusqu’à ce qu’elle ait refroidi. • Usez de prudence lorsque vous enlevez et jetez des débris de verrou des composants endommagés. Assurez-vous d’aspirer tous les débris deverre à...
  • Page 137: Pièces De Rechange

    14.0 pièces de rechange rechanges AVERTISSEMENT • Omettre de positionner les pièces conformément à ce manuel ou d’utiliser uniquement des pièces spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de remplace- ment.
  • Page 138: Vue D'ensemble

    pièces de rechange W415-2835 / 01.16.20...
  • Page 139: Assemblage De La Soupape Millivolt

    pièces de rechange W415-2835 / 01.16.20...
  • Page 140 pièces de rechange W415-2835 / 01.16.20...
  • Page 141: Accessoires

    15.0 accessoires W415-2835 / 01.16.20...
  • Page 142: Guide De Dépannage (Électronique)

    16.0 guide de dépannage (électronique) guide de dépannage AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. •...
  • Page 143 guide de dépannage (électronique) symptôme problème solution La veilleuse ne s’allume Câblage: pénurie, connexion Vérifi ez qu’il n’y a pas de connexions desserrées du thermocouple ni sonde de fl amme. pas. Il y a du bruit mais desserrée (rectifi cation de la Vérifi...
  • Page 144 guide de dépannage (électronique) symptôme problème solution Moteur tourne, les Les piles du récepteur sont Remplacez les piles. bips fréquent se faibles. produit. Lumières ou la souf- L’interrupteur de contrôle est Vérifi ez que l’interrupteur « on/off » est en position « I », ce qui fl...
  • Page 145: Guide De Dépannage (Millivolt)

    17.0 guide de dépannage (millivolt) guide de dépannage (électronique) AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. •...
  • Page 146 guide de dépannage (millivolt) symptôme problème solutions La veilleuse ne Aucune étincelle au brûleur de la Vérifi ez si la veilleuse peut être allumée avec une allumette. s’allume pas. veilleuse. Vérifi ez si le fi l est raccordé au bouton-poussoir d’ignition. Vérifi...
  • Page 147: Garantie

    18.0 garantie garantie Les produtits Napoléon sont fabriqués conformément aux normes strictes du Système de Gestion de la Qualité mondialement reconnu ISO 9001 : 2015. Les produits Napoléon sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi...
  • Page 148 À À À T IO ODUITS CONFORT 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Téléphone: 1-866-820-8686 napoleon.com...

This manual is also suitable for:

Ascent b36B36ntr-1B36ntre-1B36ptr-1B36ptre-1

Table of Contents