DA6-SSI/A-U
Menu
Reset
A Reset command is available to store the actual SSI
position to register „Zero Position". As a result, the
display value will become zero at the actual encoder
position, and all further operation will refer to this
new datum point. The zero position remains
memorized also after power-down.
no:
Reset function disabled
Front: Reset function by the front SET key
E_tErn: Reset function by the remote Reset input
FR u E: Reset via key and remote input
Zero Position: *)
Defines the zero position of the display. When you
set this parameter to e.g. "1024", the unit will
display zero when the encoder position is 1024.
Zero Position can be set directly via keypad or by
means of an external Reset command.
P01_X **)
Linearization Point 1_X
X value of the first interpolation point.
P01_Y
Linearization Point 1_Y
Y value of the first interpolation point.
P16_X
Linearization Point 16_X
X value of the 16. interpolation point.
P16_Y
Linearization Point 16_Y
Y value of the 16. interpolation point.
*) Please observe that Parameter P_Fac will cause an additional displacement of the zero position
**) Parameters P01_X to P16_Y appear only when the linearization has been enabled in the basic menu
IX34510a_e.doc / Apr-11
...
Setting Range
Default
-199999
0
...
999999
-199999
999999
... 999999
-199999
999999
... 999999
-199999
999999
... 999999
-199999
999999
... 999999
Page 17 / 43