Qualified Installing Agency - Procom PCNSD25TA Owner's Operation And Installation Manual

Vent-free gas stove
Table of Contents

Advertisement

1. Do not place Propane/LP supply tank(s)
inside any structure. Propane/LP supply
tank(s) must be placed outdoors.
2. This heater shall not be installed in a
bedroom or bathroom.
3. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See
Air for Combustion and Ventilation, pages
7 and 8. If heater keeps shutting off, see
Troubleshooting, page 25.
4. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
6. Do not run heater:
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
7. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater
off. If heated, the vapors from these prod-
ucts may create a white powder residue
within burner box or on adjacent walls or
furniture.
8. Always run heater with control knob at
PILOT/IGN, LOW (1) or HIGH (5) locked
positions. Never set control knob between
locked positions. Poor combustion and
higher levels of carbon monoxide may
result.
9. Do not use heater if any part has been
under water. Immediately call a qualified
Only a qualified agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser-
vicing. The term "qualified agency" means any
individual, firm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
4

QUALIFIED INSTALLING AGENCY

www.usaprocom.com
SAFETY
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
10. Turn off and unplug heater and let cool
before servicing. Only a qualified service
person should service and repair heater.
11. Operating heater above elevations of
4,500 feet could cause pilot outage.
12. To prevent performance problems, do
not use propane/LP fuel tank of less than
100 lbs. capacity.
13. Do not use this heater as a wood-burning
heater. Use only the logs provided with the
heater.
14. Solid fuels should not be burned in a
heater in which a vent-free log set is
installed. Do not use this heater to cook
food or burn paper or other objects.
15. To prevent sooting, follow the instructions
in Care and Maintenance (see page 24).
16. Do not add extra logs or ornaments such
as pine cones, vermiculite, or rock wool.
Using these added items can cause soot-
ing. Do not add lava rock around base.
Rock and debris could fall into the control
area of heater. After servicing, always
replace screen before operating heater.
17. This heater is designed to be smokeless. If
logs ever appear to smoke, turn off heater
and call a qualified service person.
Note: During initial operation, slight smok-
ing could occur due to log curing and the
heater burning manufacturing residues.
18. Do not use this heater if any log is broken.
Do not operate heater if a log is chipped
(dime-size or larger).
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing,
or servicing equipment; that is experienced
in such work; that is familiar with all precau-
tions required; and that has complied with
all the requirement of the authority having
jurisdiction.
200199-01B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcnsd25rta

Table of Contents