MAINTENANCE PROCEDURES
5. Wait a while to allow all oil to drain out of gearbox.
6. Install drain plug and tighten to specification.
t t i i g g h h t t e e n n i i n n g g t t o o r r q q u u e e
Gearbox drain plug
6 ± 1 Nm (53 ± 9 lbf-in)
C C h h a a i i n n c c a a s s e e F F i i l l l l i i n n g g P P r r o o c c e e d d u u r r e e
1. Open the RH side panel. Refer to Equipment .
2. Remove the check plug.