Stripe Size - Adaptec 2110S User Manual

Scsi raid controller
Hide thumbs Also See for 2110S:
Table of Contents

Advertisement

2
Change the following properties:
Property
Array tab

Stripe Size

RAID 5 Creation
By
Cache tab
Write Cache
3
Click Save to save the changes and return to the Create Array
dialog box.
Storage Manager Pro saves your changes, which are associated
with your user account. Storage Manager Pro uses these
settings whenever you use your user account to create an
array.
Stripe Size
The stripe size is the amount of data written to one drive before the
controller moves to the next drive in a stripe set (RAID 0), RAID 5
set, stripe set of mirror sets (RAID 0/1), or stripe set of RAID 5 sets
(RAID 0/5).
Description
Sets the amount of data written to one
array partition before the controller
moves to the next array partition in a
stripe set (RAID 0), RAID 5 set, stripe set
of mirror sets (RAID 0/1), or stripe set of
RAID 5 sets (RAID 0/5). See Stripe Size on
page 2-11.
(RAID 5 only) Shows the method used to
created the array. Some controllers let you
change the RAID 5 creation method.
When you create a RAID 5 set, Storage
Manager Pro uses the Verify method by
default when it creates the array. The
Verify method reads all the data on the
drives in the array and resets the parity
(redundancy) of the existing data
sequentially from the beginning of the
array to the end. The array is available to
users during the Verify process.
Enables or disables write cache. See Write
Cache Settings on page 2-12.
Creating an Array
2-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

3210sStorage manager pro v1.11

Table of Contents