ME Subsystem Configuration

Parameter
ME-HECI
Support
System Acoustic & Performance Configuration
Parameter
Throttling -
Closed Loop
Hysteresis
Temperature
(Available
when Closed
Loop is
enabled.)
Guardband
Temperature
(Available
when Closed
Loop is
enabled.)
Inlet
Temperature
Temperature
Rise
Air Flow
Description
Select Enabled to enable ME-HECI (Host
Embedded Controller Interface) support,
which will allow the Host OS to
communicate directly with the
Management Engine (ME) in a standard
method for system management,
effectively replacing the SMbus.
Description
Throttling improves reliability and
reduces power consumption in the
processor by automatic voltage control
during processor idle states.
Temperature Hysteresis is the
temperature lag (in degrees Celsius)
after the predefi ned DIMM
temperature threshold is reached before
Closed Loop Throttling begins.
This is the temperature that applies to the DIMM
temperature threshold. Each step is in 0.5
The default is [006]. Press <+> or <-> on your keyboard to
change this value.
This is the temperature detected at the chassis inlet. Each
o
step is in 0.5
C increments. The default is [070].
This is the temperature rise to the DIMM thermal zone.
o
Each step is in 0.5
C increments. The default is [020].
This is the air fl ow speed to the DIMM modules. Each step
is one mm/sec. The default is [1500].
85
Options
Enabled
Disabled
Options
Enabled
Disabled
Disabled
o
1.5
C
o
3.0
C
o
6.0
C
o
C increments.

Advertisement