Error Codes and Messages
Error Code
8505
Bad or missing memory in slot 2B
8506
Bad or missing memory in slot 1B
8600
Primary & Secondary BIOS ID's do not match
8601
Override jumper is set to force boot from lower bank of flash ROM
8602
WatchDog Timer Expired (Secondary BIOS maybe bad!)
8603
Secondary BIOS CheckSum fail
The following table indicates error codes that are sent to the Management Module for error logging as a BMC
pass-through command. All commands are of "Error" type. The syntax of error logging with the management
module and SEL is different. The same error is logged differently in the SEL than with the Management
Module.
163
Error Codes Sent to the Management Module
Error code
161
301
102
106
604
163
01298000
01298001
196
198
00019700
00019701
00150100
00150100
289
00150900
00151100
00151200
00151300
00151350
00153151
00153152
00151500
00151720
00151730
00151700
00151710
105
Error Message
Bad CMOS Battery
Keyboard failure
System Board failure (Timer tick 2 test failure)
Diskette Controller Failure
Diskette Drive? failure
Timer of the day not set
The BIOS does not support the current stepping of Processor P0
The BIOS does not support the current stepping of Processor P1
Processor cache mismatch detected
Processor speed mismatch detected
Processor P0 failed BIST
Processor P1 failed BIST
Multi-bit error occurred: forcing NMI DIMM = ??
Multi-bit error occurred: forcing NMI DIMM = ?? DIMM = ?? (could not isolate)
DIMM D?? is Disabled
SERR/PERR Detected on PCI but (no source found)
MCA: Recoverable Error Detected Proc = ??
MCA: Unrecoverable Error Detected Proc = ??
MCA: Excessive Error Detected Proc = ??
Processor MachineCheck data a Bank = ?? APIC ID = ?? CR4 = ???? ????
Processor MachineCheck Data b Address = ???? ???? ???? ???? Time Stamp
= ???? ???? ???? ????
Processor MachineCheck Data B Status = ???? ???? ???? ????
Excessive Single Bit Errors Detected
Parity Error Detected on Processor bus
IMB Parity/CRC Error
Started Hot Spare memory Copy. Failed row/rows = ?? and?? copied to spare
row/rows= ?? (used on CMIC-HE bot)
Started Hot Spare memory Copy. Failed row/rows = ?? and?? copied to spare
row/rows= ?? (used on CMIC-HE bot)
Error message
Response
Pause
Pause
Pause
Pause
Pause