Heatilator MHST36D Installation & Operating Instructions Manual page 21

Woodburning fireplace for manufactured housing
Hide thumbs Also See for MHST36D:
Table of Contents

Advertisement

MHST36D INSTALLATION INSTRUCTIONS
15. Position the Hearth Extension
Position and secure the hearth extension over the
protective metal strips that have been placed partially
under the fireplace front. These strips should extend
from the front and sides of the fireplace openings by
2 in. Seal the crack between the hearth extension
and fireplace with a bead of noncombustible
sealant. See Figure 19. Apply a noncombustible
finishing material of your choice to the hearth
extension.
Figure 19 - Position the Hearth Extension
08/04
16. Finishing Material
Do not install combustible materials over the black
face of the fireplace! This poses a safety hazard
and may start a fire. You may only use noncombustible
material over the black face of the fireplace.
a.
Combustible Material
Material which is made of or surfaced with wood,
compressed paper, plant fibers, plastics, or any
material capable of igniting and burning, whether
flame proofed or not, plastered or unplastered.
b.
Noncombustible Material
Material which will not ignite and burn. Such
materials are those consisting entirely of steel,
iron, brick, tile, concrete, slate, glass or plasters,
or any combination thereof.
c.
Noncombustible Sealant Material
Sealants which will not ignite and burn; General
Electric RTV103 Black (or equivalent), Rutland,
Inc. Fireplace Mortar #63 (or equivalent).
After completing the framing and applying the
facing material (dry wall) over the framing, a 1/2 in.
wide (maximum) bead of noncombustible sealant
must be used to close off any gaps at the top and
sides between the fireplace and facing to prevent
cold air leaks.
Only noncombustible materials may be used to
cover the black metal fireplace front.
17. Mantel
A combustible mantel may be positioned no lower
than 12 in. above the top of the fireplace opening. The
combustible mantel may have a maximum depth of
12 in. Combustible trim pieces that project no more
than 1-1/2 in. from the face of the fireplace can be
placed no closer than 6 in. from the top of the fireplace
openings. Combustible trim must not cover the black
metal surfaces of the fireplace. This mantel clearance
is in accordance with Section 7-3.3.3 of ANSI/
NFPA211.
18. Glass Doors
This fireplace has been tested and listed for use with
doors as specified in Section C, "Fireplace System
Components". Please refer to the manual packed with
each set of doors for installation instructions.
31068 Rev E
21

Advertisement

Table of Contents
loading