Heatilator MHST36D Installation & Operating Instructions Manual page 15

Woodburning fireplace for manufactured housing
Hide thumbs Also See for MHST36D:
Table of Contents

Advertisement

MHST36D INSTALLATION INSTRUCTIONS
4. Assemble the Chimney Sections
Attach either a straight chimney section or an offset to
the top of the fireplace (depending on your installation
requirement). Chimney sections are locked together
by pushing downward until the top section meets the
stop bead on the lower section.
The inner flue is placed to the inside of the flue section
below it. The outer casing is placed outside the outer
casing of the chimney section below it. See Figure 8.
WARNING!
Carefully follow the instructions for assembly
of the pipe and other parts needed to install this
fireplace system. Failure to do so may result in
a fire, especially if combustibles are too close
to the fireplace or chimney and air spaces are
blocked, preventing the free movement of cool-
ing air.
5. Install the Firestop Spacers
Mark and cut out an opening in the ceiling for the
firestop spacer being utilized (14-1/2 in. x (14-1/2 in. for
an FS338, (14-1/2 in. x (18-3/8 in. for an FS339 and
(14-1/2 in. x 23 in. for an FS340). Frame the opening
with the same dimension lumber used in the ceiling
joists.
Install the firestop spacer.
These firestop spacers are designed to provide the
minimum 2 in. air space required around the chimney.
In all situations, the firestop spacers are to be nailed
to the ceiling joists from the bottom or fireplace side,
EXCEPT when the space above is an insulated ceiling
or attic space. In this situation, the firestop spacer must
be nailed from the top side to prevent loose insulation
from falling into the required 2 in. air space around
the chimney. See Figure 9.
CAUTION:
Firestop spacers must be used whenever the
chimney penetrates a ceiling/floor area.
08/04
Figure 8
Assembling Chimney
Sections
Figure 9
Installing the Firestop Spacer
31068 Rev E
15

Advertisement

Table of Contents
loading

Table of Contents