Array Behavior When A Drive Fails - Dell EqualLogic PS6210 Hardware Owner's Manual

Table of Contents

Advertisement

PS6210 Hardware Owner's Manual
Description
Drive activity indicator (ACT LED)
Drive status indicator (PWR LED)

Array Behavior When a Drive Fails

In firmware version 7.0 and higher (and also in versions 5.2.5, 6.0.1 and higher) Dell implemented a
copy-to-spare operation to replace failing drives. This operation can, in many cases, improve the
performance of the drive replacement process by avoiding a full RAID rebuild and as a result can
provide better reliability.
If a drive fails, replace it. Do not reinstall it in the array.
8
Figure 8: LEDs on 3.5-inch Drives
Figure 9: LEDs on 2.5-inch Drives
Table 4: Drive LED States
Indicator States
Blinking green: Drive is busy
Steady green: No drive activity
Off: Drive is a spare, and spun down
Green: Drive OK
Amber: Drive failed
Off: No power to drive