UPSI-1208DPx
CONNECTION DATA INPUT / OUTPUT
Connection method
Conductor cross-section solid
Conductor cross-section flexible
Conductor cross-section with ferrule
Stripping length
Tightening torque
ENERGY STORAGE UPSI-1208DP2
Charging method
Nominal voltage U
N
End-of-charge voltage
Charging current
Undervoltage protection
Battery technology
Nominal capacity
Charging time (I_charge_max)
Buffer time (I
)
N
ENERGY STORAGE UPSI-1208DP3
Charging method
Nominal voltage U
N
End-of-charge voltage
Charging current
Undervoltage protection
Battery technology
Nominal capacity
Charging time (I_charge_max)
Buffer time (I
)
N
Revision 1-5
Screwable plug connector
0.129 mm² ... 1.31 mm² (26 ... 16 AWG)
0.129 mm² ... 1.31 mm² (26 ... 16 AWG)
0.129 mm² ... 1.31 mm² (26 ... 16 AWG)
6 mm ... 7 mm
0.3 Nm ... 0.4 Nm
CC / CV / CP
8.3 V
8.3 V
16 A max.
4.5 V
EDLC (Supercap)
5.73 kJ (3.88 kJ useful) / 1.59 Wh (1.08 Wh useful)
2 min
30 sec
CC / CV / CP
9.6 V
10.4 V
≤2 C (4.5...5 A)
6.6 V
LiFePO4
2.5 Ah / 25 Wh
34 min
11 min 30 sec
12