ANTAIRA LMP-0602 Series User Manual

ANTAIRA LMP-0602 Series User Manual

6-port industrial poe+ managed ethernet switch, with 4*10/100tx (30w/port) and 2*100fx, 48~55vdc power input

Advertisement

Quick Links

Antaira Industrial Ethernet Switches
LMP-0602 Series User Manual V1.1
LMP-0602 Series
6-Port Industrial PoE+ Managed Ethernet Switch, with
4*10/100Tx (30W/Port) and 2*100Fx, 48~55VDC Power Input
User Manual
Version 1.2
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LMP-0602 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ANTAIRA LMP-0602 Series

  • Page 1 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.1 LMP-0602 Series 6-Port Industrial PoE+ Managed Ethernet Switch, with 4*10/100Tx (30W/Port) and 2*100Fx, 48~55VDC Power Input User Manual Version 1.2...
  • Page 2 Trademark Information Antaira is a registered trademark of Antaira Technologies, LLC, Microsoft Windows and the Windows logo are the trademarks of Microsoft Corp. NetWare is the registered trademark of Novell Inc. WMM and WPA are the registered trademarks of Wi-Fi Alliance.
  • Page 3 This manual supports the following models: LMP-0602-M  LMP-0602-S3  LMP-0602-M-T LMP-0602-S3-T   LMP-0602-ST-M LMP-0602-ST-S3   LMP-0602-ST-M-T LMP-0602-ST-S3-T   This document is the current official release manual. Please check our website (www.antaira.com) for any updated manual or contact us by e-mail (support@antaira.com).
  • Page 4: Table Of Contents

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Table of Contents 1. Introduction ..............1 1.1 Product Overview ..........1 1.2 Product Software Features ........ 1 1.3 Product Hardware Features ....... 2 1.4 Package Contents ..........2 1.5 Safety Precaution ..........3 2.
  • Page 5 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.1.1 About Web-Based Management ....13 5.2 Basic Setting ............ 14 5.2.1 System Information ........14 5.2.2 Admin &Password ........15 5.2.3 IP Setting............. 16 5.2.4 System Time ..........17 5.3Port Management ..........18 5.3.1 Port Status ..........
  • Page 6 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.6.2 RSTP Configuration ........33 5.6.3 MSTI Status ..........35 5.6.4 MSTI Configuration ........36 5.7. 802.1Q VLAN ..........38 5.7.1 802.1Q VLAN settings ........ 38 5.7.2 802.1Q VLAN Settings ........ 39 5.8.
  • Page 7 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.12.2 System Event Log ........49 5.12.3 SMTP Setting ..........50 5.12.4 Event Selection ......... 51 5.12.5 Fault Alarm ..........51 5.13 MAC Table ............. 52 5.13.1 MAC Address Table ........52 5.13.2 MAC Table Configuration ......
  • Page 8: Introduction

    LMP-0602 Series User Manual V1.1 1. Introduction All Antaira industrial managed switches come with a pre-installed “user friendly” web console interface, which allows users to easily configure and manage the units, whether one is using a serial console and command line interface (CLI) commands like Telnet, SSH, HTTP (Web GUI) or simple network management protocols (SNMP).
  • Page 9: Product Hardware Features

    Installation in pollution degree to environment  DIN-Rail and wall mount design  1.4 Package Contents  1– LMP-0602 series: 6-port industrial PoE+ managed Ethernet switch, with 4*10/100Tx (30W/Port) RJ45 ports, and 2*100Fx (SC/ST) fiber ports.  1-Product CD  2-Wall mounting brackets and screws ...
  • Page 10: Safety Precaution

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 1.5 Safety Precaution Attention: If the DC voltage is supplied by an external circuit, please use a protection device on the power supply input. The industrial Ethernet switch’s hardware specs, ports, cabling information, and wiring installation will be...
  • Page 11: Hardware Description

    2. Hardware Description 2.1 Physical Dimensions Figure 2.1, below, shows the physical dimensions of Antaira’s LMP-0602 series: 6-port industrial PoE+ managed Ethernet switch with 4*10/100Tx (30W/Port), and 2*100Fx (SC/ST) fiber ports. (W x D x H) is 46mm x 99mm x 142mm Figure2.1...
  • Page 12: Front Panel

    Figure2.2 The Front Panel of LMP-0602 Series 2.3 Top View Figure 2.3, below, shows the top panel of the LMP-0602 series switch that is equipped with one 6-pin removal terminal block connector for dual DC power inputs (48~55VDC). Figure2.3 Top Panel View of LMP-0602 Series...
  • Page 13: Led Indicators

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 2.4 LED Indicators There are LED light indicators located on the front panel of the industrial Ethernet switch that display the power status and network status. Each LED indicator has a different color and has its own specific meaning, see below in Table 2.1.
  • Page 14 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2  RJ-45 Pin Assignments (Table 2.2) Pin Number Assignment Table 2.2 RJ45 Pin Assignments Note “+” and “-” signs represent the polarity of the wires that make up each wire pair.
  • Page 15: Fiber Port

    LMP-0602 Series User Manual V1.2 2.6 Fiber Port Antaira’s LMP-0602 series provides different models to support two major fiber optical ports and optional models for SC or ST type fiber connectors. The multi-mode up to 2 km, 1310 nm in 50/125 µm, 62.5/125 µm The single-mode in 30km, 1310 nm in 9/125 µm...
  • Page 16: Wiring The Power Inputs

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 2.8 Wiring the Power Inputs Please follow below steps to insert the power wire. 1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the terminal block connector as shown below in Figure 2.7.
  • Page 17: Mounting Installation

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 3. Mounting Installation 3.1 DIN-Rail Mounting The DIN-Rail is pre-installed on the industrial Ethernet switch from the factory. If the DIN-Rail is not on the industrial Ethernet switch, please see Figure 3.1 to learn how to install the DIN- Rail on the switch.
  • Page 18: Wall Mounting

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 3.2 Wall Mounting Follow the steps below to mount the industrial Ethernet switch using the wall mounting bracket as shown below in Figure 3.4. 1. Remove the DIN-Rail bracket from the industrial Ethernet switch by loosening the screws.
  • Page 19: Hardware Installation

    LMP-0602 Series User Manual V1.2 4. Hardware Installation 4.1 Installation Steps This section will explain how to install Antaira’s LMP-0602 series: 6-port industrial PoE+ managed Ethernet switch with 4*10/100Tx (30W/Port) RJ45 ports and 2*100Fx (SC/ST) fiber ports. Installation Steps 1. Unpack the industrial Ethernet switch from the original packing box.
  • Page 20: Web Management

    This section introduces the configuration by web browser. 5.1.1 About Web-Based Management All of Antaira’s industrial managed switches are embedded with HTML web console interfaces that have a flash memory on the CPU board. It is a “user friendly” design with advanced management features that allow users to manage the switch from anywhere on the network through any Internet browser, such as Internet Explorer (version 9.0 or above is recommended),...
  • Page 21: Basic Setting

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 3. The login screen appears. 4. Key in the default username: admin and password admin. 5. Click “Login” button, then the main (status) page of the Web Console will appear as below Figure 5.2.
  • Page 22: Admin &Password

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Terms Value Description Factory Default: Switch *Users can assign any name label to identify this managed node. By convention, a domain name is a text string drawn from System Name the alphabet (A-Z, a-z), digits (0-9), minus sign (-). No space characters are permitted as part of a name.
  • Page 23: Ip Setting

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Terms Value Description New Password Users can assign a New Password, and the maximum allow string length is 0 to 31 characters. Confirmation Re-type the new password. Click “Apply” to save changes.
  • Page 24: System Time

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Subnet Mask Assign the subnet mask of the IP address. If DHCP client function is enabling, user does not require to assign the subnet mask Gateway Assign the network gateway for the switch. If DHCP client function is enabling, user does not require to assign the Gateway.
  • Page 25: Port Management

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.3Port Management 5.3.1 Port Status The following information provides the current port status. Figure 5.11 – Port Status Interface 5.3.2 Port Configuration Users can assign or insert a “value/label” for each port under each “Port Name” box; enable or disable each port function;...
  • Page 26: Poe (Power-Over-Ethernet)

    Figure 5.13 – Port Configuration Description 5.4PoE (Power-over-Ethernet) LMP-0602 series is one of Antaira’s industrial PoE+ managed switches that has four built-in IEEE802.3at complaint ports, and each PoE port would support PoE output power up to a maximum of 30W per port. It is also backward compatible with IEEE 802.af to support any standard PoE powered devices (PD).
  • Page 27: Ping Alarm

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Terms Value Description Port No. PoE Port Number Any PoE port will automatically detect any PD (Powered Device) is Status connected and display the situation. Users can use the dropdown box to enable or disable any PoE port...
  • Page 28: Poe Schedule

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.4.3 PoE Schedule For energy saving or power recycle powered devices, the PoE managed switch’s PoE schedule interface allows users to appoint any date and time to enable or disable PoE functions for each PoE port.
  • Page 29: Erps

    Antaira is proud to introduce and implement Ethernet Ring Protection Switching (ERPS) protocol as a standard ring solution for network redundancy with all new industrial managed Ethernet switches.
  • Page 30: Erps Status

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.5.1 ERPS Status Below, Figure 5.18, shows the network redundancy ring status with the Ethernet Ring Protection Switch (ERPS) protocol. Figure 5.18 – Redundant Ring Network – ERPS Status 5.5.2 ERPS Configuration Figure 5.19, shows the ERPS configuration interface.
  • Page 31 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Terms Value Description Protocol “Enable” or “Disable” ERPS protocol ERPS ring port 0, it could be map to real switch port 1 – port 6. Ring Port 0 Do not set the same as Ring port 1.
  • Page 32: Before Configuring Erps

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.5.3 Before Configuring ERPS Before configuring ERPS, the rapid spanning tree protocol (RSTP), or multiple spanning tree protocol is required to disabled, due to only one protocol is exclusive running within a switch.
  • Page 33 In order to achieve the loop-avoidance mechanism, ITU-T G.8032 defines three roles in ERPS, which are “RPL Owner Node”, “RPL Neighbor Node”, and “Normal Node”. Below are two scenarios describing how to configure the ERPS in Antaira Industrial Managed Ethernet Switches. Users can reference it to configure the managed switch as...
  • Page 34 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.5.3.1 Scenario A – RPL configured Architecture Under this scenario A, there are three major roles are required to be configured within the ERPS configuration. Figure 5.24 – RPL-configured Architecture Caution: Before enabling any ERPS protocols on any of the Ring Nodes, please DO NOT connect all switches to form a loop (ring) network yet.
  • Page 35 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 [RPL Owner Node] There is only one RPL Owner Node could be set in a ring network. In order to set up the RPL Owner Node, choose a switch and enable “Protocol” under the ERPS Configuration interface, and follow below steps and use below figure 5.25 as example:...
  • Page 36 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 [RPL Neighbor Node] Users should choose a second managed switch that is adjacent to the first managed switch and set it up as the RPL neighbor node. For configuration, users should login to the second managed switch’s ERPS configuration interface and choose a specific port number under...
  • Page 37 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 [Normal Node] Then user should setup the rest of the managed switches’ “Role” of both “Ring Port 0 and 1” as “Normal Node” as shown above in Figure 5.27. Please be sure no duplicate port number has been chosen within a managed switch’s ERPS ring setting, the incorrect configurations...
  • Page 38 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.5.3.2 Scenario B – Non-configured Architecture In some situations, users can choose not to configure the RPL owner and neighbor node; the ERPS could still work well under the mechanism by blocking one of the ring ports in the ERPS ring topology.
  • Page 39: Spanning Tree

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Figure 5.29 – Non-configured Architecture setup 5.6 Spanning Tree The Spanning Tree Protocol (STP), defined in the IEEE Standard 802.1d, can be created within a mesh network of connected layer-2 switches.
  • Page 40: Rstp Status

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.6.1 RSTP Status Below Figure 5.30 shows the RSTP algorithm results. Figure 5307 – RSTP Information Interface 5.6.2 RSTP Configuration Users can enable/disable the RSTP function, and set the parameters for each port.
  • Page 41 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Terms Value Description Users can select RSTP or MSTP function to be enabled or Mode disabled before configuring the related parameters. A value used to identify the root bridge. The bridge with...
  • Page 42: Msti Status

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 The port includes the STP mathematic calculation. Admin Non STP True is not including STP mathematic calculation. False is including the STP mathematic calculation. Click “Apply” button to save changes. Figure 5.32 – RSTP Configuration Terms & Value Description MSTP (Multiple Spanning Tree Protocol) It is defined in IEEE 802.1s, it can map a group of VLAN’s into a single Multiple Spanning Tree...
  • Page 43: Msti Configuration

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.6.4 MSTI Configuration Users can display the MSTI root status and port status by selecting the “Instance ID” number from 1 to 15 by clicking on the dropdown box from the “MSTI Status” interface.
  • Page 44 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Click “Apply” button to save changes. Figure 5.35 – MSTI Configuration –Terms & Value Description Figure 5.36 – MSTI Port Configuration Interface Terms Value Description User can select Instance Tab #1~#15 to configure each Instance Tabs MSTI port “Cost”...
  • Page 45: 802.1Q Vlan

    PVID. All of Antaira’s industrial managed switches’ have a default VLAN setting set to “none” for each port, so the users can login to the VLAN setting interface to create a VLAN Group name and choose “Tag”...
  • Page 46: 802.1Q Vlan Settings

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.7.2 802.1Q VLAN Settings Figure 5.39 – 802.1Q VLAN Settings Interface Terms Value Description PVID User can assign a Port VLAN ID for each port User can choose any port be “Tagged” or “Untagged”.
  • Page 47: Igmp Settings

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 decreases the workload at the end hosts since their network cards (or operating system) will not receive and filter all the multicast traffic generated in the network. IGMP has 3 versions, IGMP v1, v2, and v3, and support query group up to 256 groups.
  • Page 48: Igmp Snooping Status Table

    Traffic Prioritization includes three modes: port base, 802.1p/COS, and TOS/DSCP. By traffic prioritization function, users can classify the traffic into four classes for differential network application. All of Antaira’s industrial managed switches support four priority queues.
  • Page 49: Qos Classification

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.9.1 QoS Classification Figure 5.44 – QoS Classification Interface Terms Value Description User can set it as “Weighted” or “Strict” Weighted mode: An 8, 4, 2, 1 weighting is applied to each round robin priority queue.
  • Page 50: Cos Mapping

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 7 is the Lowest Click “Apply” button to save changes. Figure 5.45 – QoS Classification Terms & Value Description 5.9.2 CoS Mapping Figure 5.46 – CoS Mapping Interface Terms Value Description User can assign each port a CoS value from 0 to 7.
  • Page 51: Tos Mapping

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.9.3 ToS Mapping ToS is an acronym for Type of Service. It is implemented as the IPv4 ToS priority control. It is fully decoded to determine the priority from the 6-bit ToS field in the IP header. The most significant 6 bits of the ToS field are fully decoded into 64 possibilities, and the singular code that results is compared against the corresponding bit in the IPv4 ToS priority control bit (0~63).
  • Page 52: Port Mirroring

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.10 Port Mirroring Enable or disable mirroring feature. When enabled, a copy of matched frames will be mirrored to the destination port specified in the port mirroring interface. Figure 5.50 – Port Mirroring Configuration Interface...
  • Page 53: Snmp

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.11 SNMP Simple Network Management Protocol (SNMP) is the protocol developed to manage nodes (servers, workstations, routers, switches and hubs etc.) on an IP network. SNMP enables network administrators to manage network performance, find and solve network problems, and plan for network growth.
  • Page 54: Snmp Trap Setting

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.11.2 SNMP Trap setting Figure 5.54 – SNMP Trap Setting Terms Value Description Enable SNMP Trap Enable SNMP Trap function by check the box User could insert the Server IP address as Trap...
  • Page 55: System Warning

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.12 System Warning System warning function is very important for managing a switch. Users can manage the switch by “Syslog”, “System Event Log”, and “Email Server” setup for Advanced Notice in any event type, “Event Type Selection”, and “Fault Alarm”...
  • Page 56: System Event Log

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Click “Apply” button to save changes. Figure 5.57 – SYSLOG Setting Terms & Value Description 5.12.2System Event Log Users can view and display the system event log by clicking the “Apply” button on the right bottom corner of the interface.
  • Page 57: Smtp Setting

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.12.3 SMTP Setting The Simple Mail Transfer Protocol (SMTP) is for e-mail transmission across the Internet. Figure 5.59 – SMTP Setting Interface Terms Value Description E-mail Alert Enable/Disable transmission system warning events by e-mail.
  • Page 58: Event Selection

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.12.4 Event Selection Users can select any event type through the “Event Selection” interface, such as “System Cold Start”, any ports’ “Link Up”, “Link Down”, “Link Up & Link Down” and send the system warning massage to either SYSLOG or SMTP, or both at the same time.
  • Page 59: Mac Table

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.13 MAC Table The MAC address table is the filtering database that supports queries by the forwarding process, as to whether a frame received by a given port with a given destination MAC address is to be forwarded through a given potential transmission port.
  • Page 60: Maintenance

    Antaira is continuously developing new functions and features for specific application requirements for the industrial managed switches. Users can download the latest firmware from Antaira’s website and store it within their local PC, server, or USB drive. Figure 5.65 – Firmware Upgrade Interface...
  • Page 61: Reboot

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.14.2 Reboot Users can click the “Apply” button under the “Reboot” interface to reboot the switch. Figure 5.67 – Switch Reboot Interface 5.14.3 Default Users can reset the switch to “Factory Default” by click the “Apply” button under the default interface.
  • Page 62: Save

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 5.15.1 Save Users can click the “Save” button under the “SAVE CONFIGURATION” interface, once all the settings had been configured. Figure 5.69 – Save Setting Interface 5.15.2 Backup & Store Figure 5.70 – Backup & Restore Setting Interface...
  • Page 63: Auto Load & Backup

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 USB Management Fill in the folder and filename and click the button of Save Running Config to USB Backup. If the folder or filename does not exist, system will generate it automatically. Ex: file1, / folder /file2.
  • Page 64: Command Line Interface Management

    6. Command Line Interface Management 6.1 About CLI Management Besides WEB-based management, LMP-0602 series also supports CLI management. Users can use console or telnet to management switch by CLI. CLI Management by RS-232 Serial Console (115200, 8, none, 1, none) Before configuring by an RS-232 serial console, use an RJ45 to DB9-F cable to connect the switches’...
  • Page 65 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Step 2: Input a name for the new connection. Step 3: Select to use COM port number...
  • Page 66 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Step 4: The COM port property settings are as follows: 115200 for “Bits per second”, 8 for “Data bits”, None for Parity, 1 for “Stop bits” and none for “Flow control”.
  • Page 67 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 CLI Management by Telnet Users can use “TELNET” to configure the switches. The default value is as below:  IP Address: 192.168.1.254  Subnet Mask: 255.255.255.0  Default Gateway: none ...
  • Page 68 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Commander Groups Group Command Mode hostname [Switch] configure system location [none] configure system contact [none] configure no system location configure no system contact configure show system uptime configure show system mac...
  • Page 69 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 ntp sync hour [time] configure ntp sync day [time] configure ntp sync month [time] configure ntp sync weekly [time] configure no ntp client enable Configure no ntp client timeserver configure no clock timezone...
  • Page 70 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 show administrate interface show name interface show link status interface show link state interface show link speed interface show duplex interface show link rx interface show link tx interface show link summary...
  • Page 71 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 disable g8032 rpl [port0 | port1] [owner | neighbor] g8032 aps-channel [channel ID] g8032 revertive g8032 clear g8032 port0 interface [interface name] g8032 port1 interface [interface name] g8032 g8032 g8032 ring-id [erps ring ID]...
  • Page 72 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 no power inline priority interface no power inline max interface show power inline interface show power inline priority interface show power inline max interface show power inline status interface show power inline power-supply...
  • Page 73 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 show spanning-tree mode configure show spanning-tree priority configure show spanning-tree forward-time configure show spanning-tree hello-time configure show spanning-tree max-age configure show spanning-tree cost interface show spanning-tree port-priority interface show spanning-tree link-type...
  • Page 74 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 event smtp interface [INTERFACE_NAME] [up | down] configure no event smtp power1 configure no event smtp power2 configure no event smtp cold-start configure no event smtp warm-start configure no event smtp authentication-failure...
  • Page 75 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 show event syslog interface [INTERFACE_NAME] [up | down] configure event alarm power1 enable configure event alarm power2 enable configure event alarm interface [INTERFACE_NAME] [up | down] configure no event alarm power1...
  • Page 76 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 no smtp receive [1 | 2 | 3 | 4] configure show smtp state configure show smtp sender configure show smtp subject configure show smtp server address configure show smtp server port...
  • Page 77 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 no snmp trap enable configure no snmp trap host configure no snmp trap version configure no snmp trap community configure no snmp trap inform retry configure no snmp trap inform timeout...
  • Page 78 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 qos map dscp [[priority_type] to tx-queue [[queue] configure qos trust [cos | dscp] interface qos default cos [cos_default_value] interface no qos queue-schedule configure no qos map cos [priority_type] configure no qos map dscp [priority_type]...
  • Page 79 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Save and Load Configuration File to/from USB CLI: enable -> configure terminal ->copy running-config usb (path) Fill in the folder and filename behind the “copy running-config usb” command. Ex: file1, / folder /file2.
  • Page 80 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 3. CLI :enable -> configure terminal ->copy usb startup-config (path) Fill in the folder and filename behind the “copy usb startup-config” command. Ex: file1, / folder /file2. 4. CLI : enable -> configure terminal ->copy usb firmware (path) Fill in the folder and filename behind the “copy usb startup-config”...
  • Page 81 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 CLI : enable -> configure terminal -> Syslog mode (usb or all) Select USB or ALL, it can auto save waning file to USB. And the file name is “message”. CLI : enable -> configure terminal ->usb auto load enable...
  • Page 82: Technical Specification

    Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 7. Technical Specification Table 7.1 has the technical specifications for Antaira’s LMP-0602 series: 6-port industrial PoE+ managed Ethernet switch with 4*10/100Tx (30W/Port), and 2*100Fx (SC/ST); 12~36VDC input. IEEE 802.3 10Base-T 10Mbit/s Ethernet IEEE 802.3u...
  • Page 83 Antaira Industrial Ethernet Switches LMP-0602 Series User Manual V1.2 Overload Current Present Power Reverse Present polarity Protection CPU Watch Dog Present 10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable; 100Base-TX: 2- Network Cable pair UTP/STP Cat. 5 cable. EIA/TIA-568 100-ohm (100m) Per Unit: Power 1 (Green), Power 2 (Green), Fault (Red);...

Table of Contents