5.4

Detecting and correction of the unbalance

5.4.1
After setting wheel dimensions, press <START> or close the safety cover (optional) to spin the wheel and start the
measurement run.
!
CAUTION:
5.4.2
At the end of the spin the wheel will brake automatically and the display will show the weight position and weight requirement
to correct the wheel's unbalance.
5.4.3
If unbalance shown is GOOD, press <FINE> to show residual unbalance.
F
. 28: inside weight indication
IG
G
NOTE:
OPT light blinking after the measurement indicates that static unbalance is exceeding more than 30grs.
Optimization procedure is suggested.
5.5

How to apply the weight using ALU-SE applicator

Wheel start automatically when safety cover is closed.
Place the weight ( Fig. 31 ).
Turn the wheel to the position ( Fig. 28,
Fig. 29).
Move the rod until
display ( picture at left ).
Apply the weight ( Fig. 31, Fig. 32).
F
. 29: outside weight indication
IG
///
appears on the
F
. 31
IG
F
. 32
IG
5-5