MULTIQUIP WBH-16F Operation And Parts Manual page 32

Power buggy
Hide thumbs Also See for WBH-16F:
Table of Contents

Advertisement

ADDING HYDRAULIC OIL
1. Check the hydraulic oil level in the hydraulic oil tank,
by reading the hydraulic oil sight glass (Figure 38)
mounted on the hydraulic oil tank.
Figure 38. Hydraulic Oil Sight Glass
2. If the hydraulic oil level is low, fill to the proper level with
EXXON/MOBIL NUTO H 46 or equivalent.
3. To gain access to the hydraulic oil tank filler hole, the
tub (Figure 39) must be placed in the dump position
(vertical).
4. Start the engine as outlined in the starting procedure,
then place the tub in the dumping position.
DUMP CONTROL
Figure 39. Tub Dump Position
Hydraulic Oil Access
WBH-16 SERIES POWER BUGGY • OPERATION AND PARTS MANUAL — REV. #2 (09/12/19) — PAGE 31
TUB (BUCKET)
SUPPORT
ROD
LEVER
DUMP PEDAL
5. Use the tub support rod to support the tub, then turn
the engine OFF.
6. Remove the two bolts that secure the access
cover(Figure 40) to the buggy frame.
Figure 40. Access Cover
7. Lift up on access door and secure latch.
8. Remove the hydraulic oil filler cap (Figure 41), and add
hydraulic oil as required. Fill to the normal operating
mark as indicated on the hydraulic oil sight gauge.
HYDRAULIC
OIL TANK
Figure 41. Adding Hydraulic Oil
NOTICE
In climates where temperatures are below 35°F (1.6°C),
hard starting may occur. In these cases, the hydraulic oil
should be switched to a thinner 15 weight hydraulic fluid.
MAINTENANCE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wbh-16Wbh-16eWbh-16efWhiteman series

Table of Contents