TUB (BUCKET) DUMPING
The hydraulic dump can be controlled by the hand dump
control lever or foot dump pedal.
1. To place the tub in the vertical position (Figure 26)
press down on the dump pedal or move the dump
control lever forward. The tub will move to the vertical
position as long as pressure is continuously applied
to the dump pedal or the dump control lever is held in
the forward position.
DUMP CONTROL
Figure 26. Tub Vertical Position
NOTICE
DO NOT activate dump mechanism (tub/bucket) if
buggy is facing down hill. The possibility exist of the
buggy tipping over causing equipment damage and
severe bodily harm.
NOTICE
Releasing either one (dump control lever or pedal)
before dump is completed, will cause the tub to return
to the horizontal position.
WBH-16 SERIES POWER BUGGY • OPERATION AND PARTS MANUAL — REV. #2 (09/12/19) — PAGE 25
TUB (BUCKET)
LEVER
DUMP PEDAL
2. To return the tub to the horizontal position (Figure 27),
simply release the dump control lever or remove your
foot from the dump pedal.
TUB (BUCKET)
DUMP CONTROL
LEVER
Figure 27. Tub Horizontal Position
SHUTDOWN (NORMAL)
Correct shutdown is important to safe operation. Follow
these general steps:
1. Come to a full stop.
2. Engage the parking brake (Figure 19).
3. Place the throttle lever (Figure 15) in the slow position.
Idle engine 3-5 minutes for gradual cooling.
4. Place the ignition switch key in the OFF position.
5. Place the fuel valve lever in the OFF position
6. Cycle hydraulic controls to eliminate residual pressure.
7. Remove ignition key.
8. Block wheels if on a slope or incline.
OPERATION