Bulletin 1609 Industrial Uninterruptible Power Supply
(Cat 1609-B)
ATTENTION: Please read and save these instructions. This manual contains important instructions for the Bulletin 1609 Uninterrupt-
ible Power Supply. Follow these instructions during the unpacking, installation and maintenance of the UPS. If you have a problem
with the UPS, please refer to this manual and the User Manual trouble shooting section before calling Technical Services.
Contents for UPS Include:
• Installation Instruction
•1609-B
•USB Cable
•CD
•1 Battery Jumper Wire (inside the battery compartment)
•Battery Harness (inside the battery compartment)
Note: Batteries are not included with the UPS.
Additional Resources
1. Go to http://www.rockwellautomation.com/literature
2.
Go to Search, select Publication Number.
3. Type the Publication Number in the search box and press enter.
1609-IN014 (1609-SPD Installation Instructions)
1609-UM007 (1609 UPS Management Software User Manual)
1609-UM009 (1609 UPS User Manual)
Install the 1609 UPS in the Appropriate Environment
Do not operate the UPS where there is excessive dust or the temperature or humidity is outside the
speci ed limits. The maximum ambient temperature is 40 degree Celsius using the 1609-SBAT or 50 degree
Celsius using the 1609-HBAT. The maximum humidity specification is 95% RH (Non-condensing).

Advertisement

Table of Contents
loading

Summary of Contents for Allen-Bradley 1609

  • Page 1 Bulletin 1609 Industrial Uninterruptible Power Supply (Cat 1609-B) ATTENTION: Please read and save these instructions. This manual contains important instructions for the Bulletin 1609 Uninterrupt- ible Power Supply. Follow these instructions during the unpacking, installation and maintenance of the UPS. If you have a problem with the UPS, please refer to this manual and the User Manual trouble shooting section before calling Technical Services.
  • Page 2 Batteries Wiring and Installation Instruction for the UPS Only use battery wires that have been provided with the UPS. Warning: Do not service the 1609-SPD without disconnecting the power sources due to electric shock harzard for risk of severe injury or death.
  • Page 3: Mount The Ups

    (torque of 8.7+/-1.7 lb-in). Mount the UPS The 1609-B products are designed to mount to heavy duty DIN-rail (see Diagram 1 below). The 1609-B products are also designed with an option bracket assembly (1609-BRK) that allows it to mount to either the panel or floor (see Diagram 2 below).
  • Page 4: Hardwire Ups

    Bulletin 1609 Industrial Uninterruptible Power Supply Hardwire UPS Wiring of the UPS should be performed by a qualified electrician using the appropriate wire gauges. Selection of Cables: AC Main Input / Output Wiring for UPS: Item Speci cation Wire size...
  • Page 5: Recommended Battery For Use With The Ups

    Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from the batteries. b) When replacing batteries, replace with the same number of the 1609 battery packs supplied by Rockwell Automation.
  • Page 6: Dry I/O Contacts

    ENABLE Manual Enable/Disable/Self-test The Power Button on the front of the UPS is used to manually enable or disable the output of the 1609-B UPS. To enable the 1609-B UPS, press and hold the Power Button until one beep is heard.
  • Page 7: Remote Enable/Disable

    Bulletin 1609 Industrial Uninterruptible Power Supply Remote Enable/Disable An external switch connected to the Dry I/O terminals 7 and 8 is required to remotely Enable or Disable the UPS output. 8 7 6 5 4 3 2 1 To enable the UPS, close the switch that is connected to the Dry I/O terminals 7 and 8.
  • Page 8 IATA regulations. The battery(s) may remain in the UPS. If the UPS requires service do not return it to the dealer. Follow these steps: 1. Review the problems discussed in the trouble shooting section of the 1609 UPS User Manual to eliminate common problems.

This manual is also suitable for:

1609-b

Table of Contents