2 Data

ULTRAFLOW® 54 and ULTRAFLOW® 34

2.1 Electrical data

Supply voltage
Battery
(Pulse Transmitter/
Pulse Divider)
Replacement interval
Mains supply
(Pulse Transmitter/
Pulse Divider)
Power consumption,
mains supply
Backup mains supply
Cable length,
Flow sensor
Pulse Transmitter/
Pulse Divider
Cable Extender Box
EMC data

2.2 Mechanical data

Metrological class
Environmental class
Mechanical environment
Ambient temperature
Protection class
Flow sensor
Pulse Transmitter/
Pulse Divider
Cable Extender Box
Humidity
ULTRAFLOW® 54
ULTRAFLOW® 34
Medium in flow sensor
Temperature of medium
ULTRAFLOW® 54
ULTRAFLOW® 34
Storage and transport
temperature, empty sensor
Pressure stage
Kamstrup A/S · Technical description · 5512-2464_A1_GB_08.2019
3.6 VDC ±0.1 VDC
3.65 VDC, D-cell lithium
 30 °C
6 years @ t
BAT
230 VAC +15/-30 %, 50 Hz
24 VAC ±50 %, 50 Hz
 1 W
Integral SuperCap eliminates interruptions due to short-term power failures
Max 10 m
Depending on calculator. Max 100 m when connected to MULTICAL® (Y = 2)
Depending on calculator. Max 30 m when connected to MULTICAL® 603 or 803
Fulfils EN 1434:2015 class C, MID E1 and E2
2 or 3
Fulfils EN 1434 class C
MID M1 and M2 (M2 only flow sensor type 65-5-XXHX-XXX)
5...55 °C non-condensing, closed location (installation indoors)
IP65
IP67
IP 65
Non-condensing,  93 % RH
Condensing (periodically)
Water – recommended water quality as described in CEN TR 16911 and AGFW FW510
15...130 °C
2...130 °C or 2...50 °C
-25...60 °C
PN16, PS16 and PN25, PS25
With output module (Y=3)
When properly installed.
See paragraph 7 Installation.
At medium temperatures above 90°C, the use of flange
meters is recommended.
At medium temperatures above 90 °C or below the
ambient temperature, the calculator and Pulse
Transmitter/Pulse Divider must not be mounted on the
flow sensor. Instead wall mounting is recommended.
ULTRAFLOW® 54/34