Mounting Position For Spline Shaft/Lever Type - Emerson Fisher Slurry Vee-Ball V300S Instruction Manual

Nps 3 through 12
Table of Contents

Advertisement

Instruction Manual
D103164X012
2. Clean the valve shaft and actuator lever splines to be sure the actuator lever will slide on easily. Only drive the lever
in if absolutely necessary.
3. Carefully wedge the ball solidly against the actuator‐side bearing to center the ball.
4. Keep the wedge in place while installing the lever, if necessary. Remove the wedge after you have clamped the
actuator lever on the valve shaft and have connected the lever to the actuator piston rod or diaphragm rod.
Determining Mounting Position for Spline Shaft/Lever Type
The actuator can be either right or left‐hand mounted, with the actuator on the right or left side when viewed from
upstream (see figure 8).
For right‐hand mounting (standard), the ball will be in the top of the valve body when the valve is open and the shaft is
horizontal. In this position the ball rotates CW to Close.
For left‐hand mounting, the ball will be in the top of the valve body when the valve is open and the shaft is horizontal.
In this position the ball rotates CCW to Close.
Figure 8. Index Marks for Actuator Lever Orientation for NPS 3 through 12 Valves
ACTUATOR
MOUNTING
STYLE
STYLE D
PUSH
(OPTIONAL)
DOWN
LEFT-HAND
TO
CLOSE
BALL
ROTATES
STYLE C
COUNTER-
PUSH
CLOCKWISE
DOWN
TO CLOSE
TO
OPEN
STYLE B
PUSH
(STANDARD)
DOWN
TO
RIGHT-HAND
CLOSE
BALL
ROTATES
STYLE A
CLOCKWISE
PUSH
TO CLOSE
DOWN
TO
OPEN
NOTE:
1. Arrow on lever indicates direction of actuator thrust to close valve.
E0881-1
VALVE OPEN
FLOW
FLOW
FLOW
FLOW
ACTUATOR POSITION
1