Actuator Mounting - Emerson Fisher Slurry Vee-Ball V300S Instruction Manual

Nps 3 through 12
Table of Contents

Advertisement

Slurry Vee-Ball Valve
April 2021
8. Next install the packing. Fit the studs (key 17 ), packing box ring (key 14), packing set (key 15), packing follower
(key 16), and nuts (key 18). Adjust the packing tightness for use.
9. Before fitting the flow ring, tap the end of the bearing on the drive end to ensure that the ball/shroud assembly is
hard against the valve body inner recess location on the drive end.
10. Next fit the flow ring.
a. For one piece High Chrome Iron flow ring (key 4), fit into the valve body and valve body liner. Fit the gasket, (key
13) and flow ring retainer (key 5). Secure with retainer screws (key 22) and clips (key 23). Check that the ball
rotates freely.
b. For flow ring with ceramic insert, position the valve body on the valve body liner flange face with the ball secured
and facing upwards. Make sure the flow ring insert type (key 28) and flow ring insert (key 29) are clean and free of
grease and oil. Apply a bead of Loctitet 620 around the smaller outside diameter of the ceramic insert and push
the insert into the flow ring. Place shims on the upper ball face (recommended thickness 0.015 inch) and lower
the flow ring assembly into place. Secure with retainer, screws and clips. Push the insert down onto the shims
and allow the adhesive to set.
11. Coat thread of non-drive end body plug with Loctite 567 and fit gasket (key 21), spring (key 19), and plug (key 20)
to body. Tighten plug by hand until gasket contact is achieved. Continue to tighten body plug an additional
1/4-turn from gasket contact.
For service applications involving scale formation that sets up and "freezes" mating parts, supplementary
recommendations for assembly can be provided by your

Actuator Mounting

Use the appropriate actuator instruction manual, this section of this manual, and figure 8 of this manual when
mounting the actuator or changing actuator styles and positions.
1. To help ensure correct centering of the V‐notch ball (key 3) on the flow ring (key 4 or 28/29), be sure the ball is
closed when mounting the actuator (for applications other than Spring Return Fail‐Open).
Figure 7. Pin Punch
Table 7. Pin Punch Dimensions
Ball Pin Hole O
Valve Size, NPS
3 and 4
6
8 and 10
12
10
E0878
OA
Shaft Pin Hole O
0.19
0.16
0.22
0.19
0.28
0.25
0.28
0.25
Emerson sales
office.
D
0.010
OB
A
B
Min
Max
0.25
0.15
0.25
0.18
0.38
0.24
0.38
0.24
Instruction Manual
D103164X012
OC
R 0.010
MAX
C
Max
0.085
0.105
0.135
0.135
D
Min
1.45
1.85
2.2
2.6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fisher slurry vee-ball v150s

Table of Contents