Clearance.to.combustibles; Floor.protection - Regency Fireplace Products GOSFORD F300B Owners & Installation Manual

Freestanding wood fire
Table of Contents

Advertisement

MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Universal
Universal
Default Kit
Default Kit
*(1)
A
390mm
B
280mm
C
200mm
D
280mm
E
123mm
F
380mm
G
1015mm
H
1200mm
Floor Protection
A combustible floor must be protected by non-combustible material (like
tile, concrete board, or as defined by local codes) extending beneath
the heater as follows;
From Sides:123mm
From Front: 380mm
From Back: As per D above.
The floor protector should consist of 12mm thick cement fibre sheet
which has a thermal resistance of 0.8m
fibre sheet.
IMPORTANT
*.(1).The.Universal Triple Skin Default Kit.when.fitted.with.either.1.
or.2.lengths.of.130.degree.solid.back.900mm.decromesh..
*.(2).The.Universal Triple Skin Default Kit with.2.x.900mm.130.
degree.solid.back.decromesh.and.1.x.450mm.stainless.shield.fitted.
between.active.flue.and.decromesh.
*.(3).The.Universal Triple Skin Default Kit with.1.x.130.degree.
stainless.shield.x.900mm.or.1.x.900mm.130.degree.solid.back.
decromesh.+.1.x.450.mm.stainless.shield.fitted.between.active.flue.
and.decromesh.
*.(4).The.AHD Special Insulated Flue Kit.must.be.installed.with.a.
40mm.air.gap.around.the.flue.to.any.combustible.surfaces.and.the.
ceiling.ring.must.be.spaced.as.such.to.provide.an.air.gap.of.10mm.
to.the.ceiling..
The.AHD.Special.Insulated.flue.kit.must.be.installed.with.a.perfo-
rated.ceiling.plate.with.15.x.11mm.holes.and.a.250mm.diameter.x.
150mm.high.heat.shield.positioned.directly.above.the.ceiling.plate.
NOTE:.A.minimum.clearance.of.160mm.(flat.wall).or.200mm.(corner.wall).must.be.retained.for.all.wall.surfaces.to.allow.for.fan.access.and.maintenance.
Regency Gosford Freestanding Wood Fire
Universal
AHD Special
Default Kit
Insulated Kit
*(2)
*(3)
390mm
390mm
160mm
220mm
200mm
200mm
160mm
220mm
123mm
123mm
380mm
380mm
1015mm
1015mm
1080mm
1140mm
k/w for 4mm sheets of cement
2
*(3)
420mm
220mm
200mm
220mm
123mm
380mm
1015mm
1140mm
G
D
H
E
A
G
D
H
C
E
The flue pipe shall extend not less
than 4.6m above the top of the
floor protector.
NOTE: Installation must be carried
out by a licensed installer in
accordance
with AS/NZS 2918:2001.
installation
B
E
F
開能
All measurement are in mm
Tolerance±4%
Canature
材料
版本号
更改描述
签名
年月日
设计
标准化
原图号/物料号
审核
共 张
批准
工艺
C
F
E
開能
All measurement are in mm
Tolerance±4%
Canature
材料
版本号
更改描述
签名
年月日
设计
标准化
原图号/物料号
审核
共 张
工艺
批准
7
上海开能
Shanghai C
数量
比例
1
1:1
张 用于第
1
上海开
Shangh
数量
1
张 用于第
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

GosfordF300b

Table of Contents