Blade Bolt Inspection

Inspect Blade Bolt Head daily for wear as followed:
Inspect the Blade Bolt Heads daily for abnormal wear. REPLACE BOTH BLADE BOLTS on
the Blades IMMEDIATELY if either blade bolts has:
Visible cracks or
If the recessed area on blade bolt is worn off or
If Blade Bolt has gouges or chipped areas.
Failure to replace abnormally worn blade bolts may lead to catastrophic failure of the blades and ejection of the
broken part which may cause serious bodily injury or death.
Always replace Blade Bolts with new bolts whenever replacing the Blades.

BLADE CARRIER REMOVAL

Remove cotter pin and loosen slotted nut on gear box shaft. Loosen but do not remove the nut until the blade
carrier is loosened. Use a suitable two-jaw gear puller to pull carrier off tapered gear box shaft. If gear puller is
not available use long bar inserted through blade bolt access hole with end against rotor bar. Strike opposite
end of bar with sledge hammer. Rotate blade carrier 180 degrees and repeat process.