Unit Details Page - 3Ware 9650SE-2LPB-10 User Manual

Serial ata raid controller
Hide thumbs Also See for 9650SE-2LPB-10:
Table of Contents

Advertisement

Unit Details page

www.3ware.com
The operational status of the unit: OK, Rebuilding, Initializing,
Status.
Migrating, Verifying, Degraded, or Inoperable (missing drives). When a unit
is Rebuilding, Initializing, Migrating, or Verifying, the percentage (%)
complete is also shown. For an explanation of the statuses, see "Unit Statuses"
on page 140.
Note:
If an asterisk (*) appears next to the status of a unit, there is an error on one
of the drives in the unit. This feature provides a diagnostic capability for potential
problem drives. The error may not be a repeated error, and may be caused by an
ECC error, SMART failure, or a device error. To see if this error condition still exists,
rescan the controller; rescanning will clear the drive error status if the condition no
longer exists.
Check this box to cause the LED for the drives associated with this
Identify.
unit to blink in the enclosure. (This feature only applies when drives are in an
enclosure that has a Chassis Control Unit (CCU) and is connected to the I
Chassis Control connector on the 9550SX, 9590SE, or 9650SE controller.
Figure 92. Unit Details Page
The Unit Details page appears when you click an ID number on the Unit
Information page. Because it is a sub-page of Unit Information, the page title
in the menu bar continues to display "Unit Information" even when you view
details of a unit.
The Unit Details page shows details about a particular unit. The specific
information shown depends on what type of unit it is. For example, details
about a RAID 5 unit made up of three subunits, each of which contains one
Unit Details page
2
C
193

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents