Unit placement
NIMBUS AQUASLIM WH fancoils have to be installed only
in high wall position, above 2 meters.
Avoid installing the unit near:
-
areas exposed to direct sunlight;
-
heat sources;
-
in damp areas and areas in which the unit can come
into contact with water;
-
in environments with oil mists;
-
in environments subject to high frequencies.
Installation procedure
The assembly steps described below and their drawings
refer to a version of the machine with connections on the
right side.
For ideal installation and performance levels, carefully
follow the instructions in the manual.
Installation clearances
The figure shows the minimum distances required of the
fan coil from the walls and furniture on site.
20
EN / 30
Make sure that:
-
the wall on which you intend to install the unit has an
appropriate structure and capacity;
-
the wall surface is not crossed by pipelines or power
lines;
-
the wall is perfectly level;
-
there are no obstructions nearby that could
compromise the inlet and outlet airflow;
-
the wall on which you are installing the unit is (if
possible) an external perimeter wall, in order to allow
condensate drain outside the premises;
-
air flow is not directed towards by-standers.
Failure to do so may cause system malfunctions and
automatically voids the warranty, and relieves the
constructor of any harm caused to persons, animals or
property.