5. Troubleshooting

Details of Error Icons
OVERLOAD
OVERLOAD
RECHARGING TIME
RECHARGING TIME
RECHARGING TIME
OVERLOAD
OVERLOAD
OVERLOAD
If any alert occurs during the use of this product and the alert icon does not disappear after the product
is restarted, please stop using the product immediately (do not attempt to charge or discharge).
above information fails to resolve your problem, please contact customer service for further support.
Error Type
USB-A overload
icon flashes
protection
USB-C overload
icon flashes
protection
USB-C high-temperature
icon flashes
protection
Battery charging high-
icon flashes
temperature protection
Battery discharge high-
icon flashes
temperature protection
Battery charging low-
icon flashes
temperature protection
Charging overload
icon flashes
protection
AC output overload
icon flashes
protection
AC over-temperature
icon flashes
protection
AC low-temperature
icon flashes
protection
icon flashes
Fan blocking
Car charging overload
icon flashes
protection
Car charging high-
icon flashes
temperature protection
Failure of communi-
icon flashes
cation between main
control board and AC
Recovery Methods
Remove the abnormal load and normal
operation will resume automatically once
the load is normal.
Remove the abnormal load and normal
operation will resume automatically once
the load is normal.
Normal operation will resume
automatically after the product
cools down.
Normal operation will resume
automatically after the battery
cools down.
Normal operation will resume
automatically after the battery
cools down.
Normal operation will resume automat-
ically after the battery temperature is
restored to above 5°C (41°F).
Normal operation will resume
automatically after being restarted.
Normal operation will resume after
removing the over-powered device
and restarting the machine. Electrical
appliances must be used within the
rated power (for the power limit of
electrical appliances in the X-Boost mode,
please refer to the X-Boost function
introduction)
Please confirm that the air inlet and outlet
of the product are unobstructed. Normal
operation will resume automatically
once the cause is eliminated and the
temperature decreases.
Normal operation will resume
automatically after the ambient
temperature is restored.
Please check whether the fan is blocked
by foreign objects and remove the cause
of the error.
Normal operation will resume
automatically once the load is normal.
Normal operation will resume
automatically after the product
cools down.
Normal operation will resume
automatically after being restarted.
If the