H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer Safety requirements Servicing Product inspection - Inspect the equipment for shipping damage. - There are no user serviceable parts except the battery. Do not attempt to service this product or Should any damage be discovered, immediately remove covers other than the battery cover.
Key Features User friendly, handheld QAM meter. Introducing the H30+. Remote measurements and control in an affordable package. New from Televes, a go-to meter designed with the needs of a Cable TV operator in mind. Complete portfolio Analog/Digital measurements with easy-to-read pass/fail The H30+ is a light weight, rugged unit, packed indicators.
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer General Specification Display 2.8” TFT 400 x 240 full colour H30+ : 529g (1.16lb) Weight H30D+ & H30D+Adv: 633g (1.39lb) Dimensions 6.9 x 3.9 x 2 in / 175 x 100 x 52 mm (H x W x D) Input: 100-240V~ 50-60Hz AC Adaptor Output: 12VDC, 2A...
Technical Specifications Analog Measurements Freq. Range 42 MHz to 1002 MHz References Level measurement -15 to +50 dBmV (-35 to +60dBmV opt.593235) H30+ 593980 up to 30 dB H30D+ 593981 up to 54 dB H30D+ Advance 593985 Accuracy ±2 dB Frequency Resolution 0.1 dB...
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer Description of equipment IP modem, DS and US maximun speed, ping current Throughput Test and average delay, lost packets, transfer speed components Connection status of the modem, instantaneous Modem Emulation speed and size data sent through the modem PLC: Frequency, level, MER, CWE Connectors and controls Level: average, max, min...
Keyboard Power supply A DC adapter is provided to power and charge the meter. Plug the adapter into a properly grounded electrical supply and the power connector on the side of the unit. When external power is supplied, the battery management system automatically controls the Device On/Off button: To turn the charging process.
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer Battery Recommendations Product operation To maximize battery life: Avoid fully discharging the battery. 1. Docsis The battery should always be charged with the (H30D+ / H30D+Adv) battery pack attached to the device and using the supplied DC adapter or applying a constant voltage within the specified range (12-15VDC).
Page 11
1.1.1. Main window Below is a capture of a Connection window with a 1.2.1. Main window brief explanation of its features. Below is a capture of a Docsis3.1 Advanced window with a brief explanation of its features. Connection Parameters of the MAC of the Status DOCSIS network...
Page 12
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer network via the H30D+/D+Adv’s Ethernet port. 1.5.1. Main window 1.4. Throughput test Below is a capture of a Modem Emulation window with a brief explanation of its features. This function measures the upstream and downstream rates of the DOCSIS network.
Analog and digital channels are very different in terms of signal content and power distribution and thus require the advanced SLM techniques provided in the Televes H30+/D+/D+Adv. In analog mode, video and audio levels, V/A and Carrier to Noise (C/N) are measured.
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer Channel Measurements Change of the selected Channel using Frequency channel plan with pass/fail indicators 2.2. Setup Press to change the Channel Info options. - Ter. Plan: Selected Terrestrial plan. Bar graph representing all the found channels. Color according to checkmarks - Tuning: Channel, Frequency - A/D: Auto, Analog, Digital...
4.2. Setup using the remote control application Press to change the Tilt options. 4. Tilt Any number of analog, digital or DOCSIS channels can be measured using the tilt measurement, and you can even select which carriers are your reference points to determine the tilt between any of the channels included in the measurement.
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer This is a useful feature to point antennas without Span having to look at the display. Selected channel User can change it using Change using - Span: 2.5MHz, 6.25MHz, 12.5MHz, 25MHz, 62.5MHz, 125MHz, 250MHz, 500MHz, Full.
Selected channel Change using 7. Voltmeter & Hum Modulation H30+/D+/D+Adv measures the voltage present at the RF input. The HUM measurement indicates the variation in percentage of the video carrier amplitude of the TV signal. This will help you diagnose those ground and power interference problems that may result from a defective power supply or faulty/ overloaded power inserters.
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer 7.2. Setup Selected channel Change using List of measurements with pass/fail indicators Press to change Voltmeter & Hum options. - Tuning: Channel, Frequency. - Save datalog: Saves the current scan measurements. You can see the datalogs Indicates that the Bar graph representing using the remote control application.
Selected frequency Level of the Change using selected frequency 10. Speed Test Allows you to check your basic network performance parameters so you don’t need to get your laptop out. This function attempts to connect to the server (the server is selected automatically by the H30+/ D+/D+Adv by location), checks the DHCP protocol and the connection to the Internet.
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer - Volume - Info Service: On/Off info about the Service. 11. MPEG 12. LT Monitoring The H30+/D+/D+Adv’s MPEG feature will show the image of the selected service. The H30+/D+/D+Adv’s Long Term Monitoring feature allows automatic monitoring of the 11.1.
12.2. Configuration 11.1. List view Wi-Fi network’s name Power of each Wi-Fi Press to change LT Monitoring options. access point’s signal. Wi-Fi network’s MAC The list is sorted by power Wi-Fi protect access type - Measure delay: Select the time interval between two consecutive measure shots.
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer 11.2. Map view 14. Setup Graph showing the wifi networks. Each Change main configuration settings: triangle represents a network. The height of the triangle represents the power of the access point signal. - Ter.
navigation buttons and SSID: Shows the SSID of the H30+/D+/ D+Adv BSSID: Shows the SSID of the H30+/D+/ D+Adv IP: Shows the SSID of the H30+/D+/ D+Adv -Units System: Metric, Imperial - Time and Date: Set current time (hour and minutes) and As you can see in the image above, the list date (day of the month, month and year).
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer - Save Datalog: Saves the current IPTV measurements. You can see the datalogs using the remote control application. 12.1.1. Measurements This function shows necessary measurements of the selected IPTV channel. 12.1.1.1. Main Window Below is a capture of a IPTV Measurements window with a brief explanation of its feature: 16.
8.2. Setup Press OK button to automatically download and Press to change Echoes options. install the new firmware version. Web Application First of all, connect your H30+/D+/D+Adv to the network using the Ethernet connector or the Wi- Fi interface. Then you must find out the IP of your H30+ (see section 14.- Setup - Network/Wi-Fi).
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer To change the display mode from calendar mode 2. Plans to list mode, just click on the corresponding button placed at the menu bar: In this window, you can see all the channel plans of your H30+/D+/D+Adv.
You can create a new channel plan from an existing be uploaded to your H30+/D+/D+Adv, but none of one by clicking on the corresponding button. Or the channel plans in your meter will be removed. you can start from scratch, by clicking on the “New 2.4.- IPTV custom plan”...
H30+ H30D+ - CATV & DOCSIS 3.1 Meter /Analyzer file on your computer. Save the profile Then, connect other H30+/D+/D+Adv where you in the meter want to copy the configuration to and select the Display to see all the Delete profile Import feature.
Do not return the unit without first contacting original purchase, unless otherwise specified. Televes Technical Support. (B) Televes shall, free of charge and in its sole If the unit needs to be returned, Televes will discretion, either repair, replace with a new or arrange for free shipping.