2.4 Basic Setup - System Startup, Battery Protection - VENTRA XDR-450/D User Manual

5 ch hybrid hd mobile dvr (1) 720p + (4) analog hd 720p / d 1
Table of Contents

Advertisement

2.3 Startup – On / Off
1.
On / Off: How the XDR is activated (3 Modes)
-
Ignition
-
Timer
-
Ignition or Timer
2.
Ignition Delay: Time delay between vehicle ignition off to XDR powering off (0-300
seconds)
3.
Ignition: XDR powers on as vehicle ignition is on
4.
Timer : If Timer option is selected, the schedule for Start and End Time must be set .
This schedule only applies to the XDR and does not affect or shut down the vehicle
ignition
Ignition or Timer: XDR will power on from either trigger. However, both criteria have to
5.
be met in order for the XDR to power off. XDR will not shut off if the scheduled shut
down time has been reached while the vehicle ignition is still on.
2.4 Startup – Low Battery
1.
Sleep: No consumption standby
2.
Low Voltage Protect: Enable / Disable the XDR from auto shutting off when reaching
the low battery voltage threshold to prevent battery drain
3.
Battery Low Voltage: Protects the vehicle battery by setting threshold to turn off XDR
Default for 12V = 9V, 24V = 21V
4.
Voltage Startup:
When the vehicle battery is consistently greater the than set value, it
will automatically boot up.
Default for 12V = 12.5V, 24V = 24.5V
5.
Low Voltage Upload: Enable / Disable low voltage report log