PROGRAMMING WORKSHEETS

XIII.
At Default:
Output A = AUX POWER
Output B = AUX POWER
Output C = SMOKE POWER
LOC
PAGE
0
11
OUTPUT A EVENT & TIME
12
1
OUTPUT A SPECIAL FEATURES
Segment 1
1 = "On" if timed in minutes; "Off" if timed in
seconds.
2 = "On" if latched until code is entered; "Off" for
timed.
3 = "On" if output should stop time when a code is
entered.
4 = "On" for inverted output.
5 = "On" disables output during listen-in.
6-8 = Reserved
2
12
OUTPUT B EVENT & TIME
12
3
OUTPUT B SPECIAL FEATURES
Segment 1
1 = "On" if timed in minutes; "Off" if timed in
seconds.
2 = "On" if latched until code is entered; "Off" for
timed.
3 = "On" if output should stop time when a code is
entered.
4 = "On" for inverted output.
5 = "On" disables output during listen-in.
6-8 = Reserved.
4
13
OUTPUT C EVENT & TIME
5
13
OUTPUT C SPECIAL FEATURES
Segment 1
1 = "On" if timed in minutes; "Off" if timed in
seconds.
2 = "On" if latched until code is entered; "Off" for
timed.
3 = "On" if output should stop time when a code is
entered.
4 = "On" for inverted output.
5 = "On disables output during listen-in.
6-8 = Reserved.
6 & 7
13
RESERVED
16
(Defaults are printed in bold italics text.)
DESCRIPTION
DEFAULT
0 10
Segment 2
1 = Partition 1
5 = Partition 5
2 = Partition 2
6 = Partition 6
3 = Partition 3
7 = Partition 7
4 = Partition 4
8 = Partition 8
0 10
Segment 2
1 = Partition 1
5 = Partition 5
2 = Partition 2
6 = Partition 6
3 = Partition 3
7 = Partition 7
4 = Partition 4
8 = Partition 8
11 8
Segment 2
1 = Partition 1
5 = Partition 5
2 = Partition 2
6 = Partition 6
3 = Partition 3
7 = Partition 7
4 = Partition 4
8 = Partition 8
NX-320E Power Supply
DATA
_ _
_ _