Codes 61-70 Output Enable; Location 14; Codes 71-80 Output Enable; Codes 81-90 Output Enable - GE NetworX Series Installation And Startup Manual

Remote power supply
Hide thumbs Also See for NetworX Series:
Table of Contents

Advertisement

LOCATION 14

(10 segments of feature selection data)
When activating outputs with a user code (event #30), location 14 can be used to restrict certain codes from
activating certain outputs. Location 14 contains 10 segments. Segment 1 corresponds to user 61; Segment 10
corresponds to user 70. The LEDs correspond to outputs A - C (see Table XII:2 on page 14).
LOCATION 15
(10 segments of feature selection data)
When activating outputs with a user code (event #30), location 15 can be used to restrict certain codes from
activating certain outputs. Location 15 contains 10 segments. Segment 1 corresponds to user 71; Segment 10
corresponds to user 80. The LEDs correspond to outputs A – C (see Table XII:2 on page 14).
LOCATION 16
(10 segments of feature selection data)
When activating outputs with a user code (event #30), location 16 can be used to restrict certain codes from
activating certain outputs. Location 16 contains 10 segments. Segment 1 corresponds to user 81; Segment 10
corresponds to user 90. The LEDs correspond to outputs A - C (see Table XII:2 on page 14).
LOCATION 17
(9 segments of feature selection data)
When activating outputs with a user code (event #30), location 17 can be used to restrict certain codes from
activating certain outputs. Location 17 contains 9 segments. Segment 1 corresponds to user 91; Segment 9
corresponds to user 99. The LEDs correspond to outputs A - C (see Table XII:2 on page 14).
LOCATION 18
(2 segments of feature selection data)
Location 18 is used to enable the A/C delay and the Dynamic Battery Test, both of which are timed in minutes.
The factory default is 5-0, meaning the A/C power will be off for 5 minutes before a report is sent or a Service
light will illuminate, and the Dynamic Battery Test is disabled ("0" minutes). If you desire the A/C delay to be 8
minutes and the Dynamic Battery Test to be 3 minutes, you would program [8]-[3].
LOCATION 19
(8 segments of feature selection data)
Location 19 is used to enable various system features of the power supply module.
Table XII:3
LED
1
On for AC report always sent; Off follows control
If enabled, an AC Fail report will be sent if power is lost for the time programmed in Location 18.
If "off", the report will only be sent if the control panel has not sent an AC Power Lost report, and
AC Fail report is enabled in Location 37 of the panel.
2
On enables periodic Battery Test
Enables Battery Missing every 30 seconds.
3
On enables Low Battery reporting
If enabled, the power supply module will report Low Battery to the central station.
4
On enables Siren Tamper/Trouble reporting
If enabled, the power supply module will report a Siren Tamper to the central station.
5-8
Reserved
NX-320E Power Supply

CODES 61-70 OUTPUT ENABLE

CODES 71-80 OUTPUT ENABLE

CODES 81-90 OUTPUT ENABLE

CODES 91-99 OUTPUT ENABLE

A/C DELAY AND DYNAMIC BATTERY TEST

DEVICE OPTIONS

Description
15