Inspection And Maintenance - GEM Q50 eSyStep Operating Instructions Manual

Motorized pinch valve
Hide thumbs Also See for Q50 eSyStep:
Table of Contents

Advertisement

13 Inspection and maintenance

WARNING
The equipment is subject to pressure!
▶ Risk of severe injury or death.
Depressurize the plant.
Completely drain the plant.
CAUTION
Use of incorrect spare parts!
▶ Damage to the GEMÜ product.
▶ Manufacturer liability and guarantee will be void.
Use only genuine parts from GEMÜ.
CAUTION
Hot plant components!
▶ Risk of burns.
Only work on plant that has cooled
down.
CAUTION
Risk of crushing!
▶ Risk of severe injury!
Before performing any work on the
GEMÜ product, depressurize the plant.
NOTICE
Requirements for tube lines used!
▶ Use tube lines suitable for the application, see manufac-
turer's information.
Only use undamaged tube lines.
NOTICE
Lay tube lines professionally!
▶ Lay tube lines professionally and do not bend them below
the minimum bending radius, see manufacturer's inform-
ation.
Do not kink or twist the tube lines.
NOTICE
Exceptional maintenance work!
▶ Damage to the GEMÜ product.
Any maintenance work and repairs not described in these
operating instructions must not be performed without
consulting the manufacturer first.
The operator must carry out regular visual examination of the
GEMÜ products depending on the operating conditions and
the potential danger in order to prevent leakage and damage.
www.gemu-group.com
The product also must be disassembled and checked for
wear in the corresponding intervals.
1. Have servicing and maintenance work performed by
trained personnel.
2. Wear appropriate protective gear as specified in plant op-
erator's guidelines.
3. Shut off plant or plant component.
4. Secure plant or plant component against recommission-
ing.
5. Depressurize the plant or plant component.
6. Actuate GEMÜ products which are always in the same po-
sition four times a year.
7. If necessary, the end position counter User can be reset
after maintenance or other changes under parameter
Cycle Counter.
13.1 Spare parts
Item
Name
A
Actuator
1
Tube holder
2
Compressor
43 / 52
13 Inspection and maintenance
A
2
1
Order designation
-
... (OD 3/4")
... (OD 7/8")
... (ID 1/2")
GEMÜ Q50 eSyStep
Open / Close (Code AE, A5, A6)

Advertisement

Table of Contents
loading

This manual is also suitable for:

AeA5A6Esystep q50

Table of Contents