Technical Specifications
5.3 Operating Environment
5.3
Operating Environment
The RUGGEDCOM RX1500 is rated to operate under the following environmental
conditions.
Note
Temperature limits for select line modules may differ from that which can be
withstood by the RUGGEDCOM RX1500. Make sure the selected modules are
rated for the expected environmental conditions before deployment. For more
information, refer to the "RUGGEDCOM RX1500 Series Modules Catalog".
Ambient Operating
Temperature
Ambient Storage Temperature
Ambient Relative Humidity
Maximum Altitude
a
Maximum ambient operating temperature is 70 °C (158 °F) when the device is installed along with
Underwriter Laboratories (UL) listed devices.
b
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
c
Operating temperature may vary based on the limitations of installed SFPs. Refer to the "RUGGEDCOM
SFP Transceivers Catalog" for SFP temperature ratings.
d
Non-condensing.
5.4
Mechanical Specifications
Weight
Ingress Protection
Enclosure
5.5
Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
34
-40 to 85 °C (-40 to 185 °F)
abc
-40 to 85 °C (-40 to 185 °F)
d
5% to 95%
12192 m (40000 ft)
Approximately 4.7 kg (10.3 lb)
IP30
Aluminum
RUGGEDCOM RX1500