Installing a Power Module
To install a power module, do the following:
1.
2.
3.
RUGGEDCOM RX1500
Installation Manual, 10/2021, C79000-G8976-1053-21
Loosen the screws that secure the module to the chassis until the module can be
removed.
1
2
3
Chassis
1
Power Supply
2
Screws
3
Figure 4.5
Removing a Power Supply
Slide the module out of the chassis.
Disconnect the power supply wiring from the terminal block. Alternatively, for
convenience, remove the terminal block with the wiring still connected and set
it aside to be connected later to the new module.
Install a new or blank module to prevent the ingress of dust and dirt.
If equipped, remove the existing module.
If applicable, connect the supplied terminal block to the module or connect the
terminal block from the previous module.
Confirm or connect the wiring from the power supply to the module. For more
information, refer to
4.4 Installing/Removing Power Modules
"Connecting Power (Page
11)".
Modules
31