2.5.2 Connecting Low Dc Power - Siemens SIMATIC NET RUGGEDCOM RX1500 Installation Manual

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1500:
Table of Contents

Advertisement

6.
7.
2.5.2
Connecting Low DC Power
To connect a low DC power supply to the device, do the following:
Electrical hazard – risk of damage to equipment
Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block.
Damage to the power supply may occur.
Note
The RUGGEDCOM RX1500 works with both positive VDC power supplies and negative
VDC power supplies.
RUGGEDCOM RX1500
Installation Manual, 10/2021, C79000-G8976-1053-21
Using a #10 ring lug and #10-32 screw, secure the ground terminal on the
power source to the ground connection on the device. Make sure the lug is
tightened to 1.1 N·m (9.5 lbf·in).
#10 Ring Lug
1
#10-32 Screw
2
Connection from External Power Source
3
Ground Connection
4
Figure 2.8
Ground Connection
Install the safety cover over the terminal block.
NOTICE
2.5.2 Connecting Low DC Power
1
2
Installing the Device
4
3
15

Advertisement

Table of Contents
loading

Table of Contents