12.3

Tech data

Electrical data
Power infeed
Fuse size (recommended), class gL/C
Connected load
Heating system
Type of connection (heating flow,
heat pump and flow/return of the
auxiliary heater)
Type of connection (heating return)
Maximum operating pressure
Expansion Vessel
Heat transfer medium
Minimum flow (when defrosting)
Pump type PC0
General
Waste water connection
Protection index
Dimensions (width x depth x height)
Weight
Sound pressure level
Maximum possible installation
altitude of boiler above sea level
1) 1N AC, 50 Hz
34
Unit
HC7000iAW 9l
1)
V
230
A
10
kW
0.5
inch
3/4"
(external thread)
inch
3/4"
(external thread)
bar
3
I
Not integrated
l/s
0.32
Grundfos UPM2K
25-75 PWM
mm
Ø 32
IPX1D
mm
350 x 246 x 706
kg
18
dB(A)
36
m
2000
Compress Hybrid 7000i AW – 6721833053 (2020/09)