Connecting The Heating Circuit Module; Room Temperature-Dependent Controller; Connecting The Swimming Pool Mixer; Connecting Mb Lan 2 - Bosch Compress Hybrid 7000i AW Installer's Manual

Indoor unit for air to water heat pumps
Hide thumbs Also See for Compress Hybrid 7000i AW:
Table of Contents

Advertisement

Electrical connection
1
Fig. 34 Extending the flow sensor cable
[1]
Flow temperature sensor with cable
[2]
Connection terminal
[3]
Extension cable
[4]
Plug, T0 connection
6.7.3

Connecting the heating circuit module

▶ Connect the heating circuit module to the connection EMS
( Chapter 12.2 on page 33).
If an accessory is already connected at the EMS connection:
▶ Connect heating circuit modules at the EMS connection parallel to the
accessory which is already installed ( Chapter 6.7.1 on page 19).
6.7.4

Room temperature-dependent controller

As an option, underfloor heating circuits in damp areas
(e.g. bathroom or kitchen) can be controlled via the indoor unit.
▶ Connect the control of the underfloor heating circuit to connection PK2
( Chapter 12.2 on page 33).
Room sensor with integrated humidity sensor
(CR10H or ModuLine 1010H)
When installing a room sensor with integrated humidity sensor:
▶ Connect the room sensor to the connection EMS
( Chapter 12.2 on page 33).
If an accessory is already connected at the EMS connection:
▶ Connect the room sensor at the connection EMS parallel to the
accessory which is already installed ( Chapter 6.7.1 on page 19).
Room sensor without integrated humidity sensor
(CR10 or ModuLine 1010)
When installing a room sensor without integrated humidity sensor:
▶ Connect the room sensor to the connection EMS
( Chapter 12.2 on page 33).
If an accessory is already connected at the EMS connection:
▶ Connect the room sensor at the connection EMS parallel to the
accessory which is already installed ( Chapter 6.7.1 on page 19).
▶ Connect humidity sensor to the MK2 connection
( Chapter 12.2 on page 33).
22
3
1
2
0010036207-001
6.7.5

Connecting the swimming pool mixer

▶ Connect the swimming pool mixer to the EMS connection
( Chapter 12.2 on page 33 [6]).
4
If an accessory is already connected at the EMS connection:
▶ Connect the swimming pool mixer to the EMS connection parallel to the
accessory which is already installed ( Chapter 6.7.1 on page 19).
6.7.6

Connecting MB LAN 2

The MB LAN 2 serves as interface between the heating system and a
network (LAN).
The MB LAN 2 can be used to control and monitor the heating system via
1
a mobile phone.
To be able to use the MB LAN 2, the following prerequisites must be met:
• Internet access is available.
• The RJ45 output of the router is available.
• The corresponding app is installed on the mobile phone.
Additional costs may be incurred when using the Internet access for the
MB LAN 2.
▶ Connect the MB LAN 2 to the following connections:
– Power supply for MB LAN 2 12 V
– EMS
(Chapter 12.2 on page 33 [3 and 6])
If an accessory is already connected at the EMS connection:
▶ Connect the MB LAN 2 to the EMS connection parallel to the
accessory which has already been installed( Chapter 6.7.1
on page 19).
6.7.7

External inputs

NOTICE
Damage due to incorrect connection!
Connections intended for a different voltage or current can damage
electrical components.
▶ Only perform connections to the heat pump's external inputs which
are designed for 5 V and 1 mA.
▶ If an intermediate relay is required, use only relays with gold-plated
terminals.
The external inputs can be used for the remote control of certain
functions in the user interface.
Those functions which are activated by the external inputs are described
in the operating manual for the user interface.
The external inputs are connected either to a circuit breaker for manual
activation or a control device with a relay output for 5 V.
Compress Hybrid 7000i AW – 6721833053 (2020/09)