Maintenance
9.2.1
Replacing the pump
▶ De-energise the indoor unit and outdoor unit.
▶ Drain the heating system (Chapter 9.1).
▶ Remove the cover (Chapter 5.3.1).
▶ Allow the system to cool and depressurise it.
▶ Pull off 2 plugs (power supply and signal) on the pump (Fig. 37).
▶ Remove the lock screw and pull the locking plate forwards and out
(Fig. 38).
NOTICE
Damaged and leaking connector pipes!
The screw fittings and connector pipes may be damaged if excessive
torques are applied when loosening and tightening the union nuts.
▶ Use a suitable tool.
▶ Counterhold at the coupling points.
▶ Perform the disassembly and assembly correctly.
▶ Undo union nuts at the pump then remove the pump and gaskets
(Fig. 39). As you do so, counterhold at the coupling points using a
suitable tool.
▶ Insert new pump with new gaskets and fit union nuts on the pump.
Tighten the union nuts by hand then use a tool to turn them by approx. ¼
revolution.
▶ Fit locking plate.
▶ Connect cables.
▶ Fill and vent heating system (Chapter 7.1).
▶ Carry out tightness test.
▶ Restore the power supply to the indoor and outdoor unit.
2
Fig. 37 Unplug the plug
[1]
Plug for PWM signal
[2]
Plug for power supply
28
Fig. 38 Remove locking plate
1
Fig. 39 Undo union nuts
9.2.2
Replacing the temperature sensor
▶ De-energise the indoor unit and outdoor unit.
NOTICE
Malfunction of the system!
0010031769-001
The heating system could malfunction if the temperature sensor is
connected incorrectly or swapped round.
▶ Do not swap the temperature sensor round (Chapter 12.1).
▶ Establish electrical connection correctly (Chapter 12.2).
1. 1. 1.
2. 2. 2.
Compress Hybrid 7000i AW – 6721833053 (2020/09)
0010031771-001
0010031772-001