Product description
No sources of ignition such as contactors, lamps or electrical switches
are permitted within the protection zone. The defined protection zones
are also applicable for installations on pitched roofs, with the addition
that no openings to the building and no sources of ignition are allowed
below the product.
No structural changes are allowed in the protection zone that violates the
rules mentioned above for the protection zone.
2.1.1

Protection zone, ground-placed heat pump by wall

A
A
B
Fig. 1
Protection zone ground-placed
[A]
1000 mm
[B]
1000 mm
2.1.2
Protection zone, ground-placed heat pump free standing or
on a flat roof
A
Fig. 2
Protection zone ground-placed on plot or roof
[A]
1000 mm
[B]
1000 mm
[F]
Front
4
A
0010037106-006
F
B
0010037107-005
2.1.3
Protection zone, ground-placed heat pump in a corner
Fig. 3
Protection zone ground-placed in a corner
[A]
1000 mm
[B]
2000 mm
2.2

Data plate

• AW OR: The data plate is located on the rear side of the heat pump.
• Compress 5800i 12 M: The data plate is located inside of the indoor
unit. For the exact location ( the installation instructions of the
appliance).
The data plate contains information on output, item number, serial
number and date of manufacture.
2.3

Heat pump (outdoor unit)

The heat pump is inverter operated, which means that it will
automatically change the compressor speed to deliver the exact amount
of energy required at the moment. The fan is also RPM controlled and will
change its speed as needed. This provides the lowest possible energy
consumption.
The speed changes have an effect on the sound emissions, as higher
speed results in higher sound emission.
Defrosting
Ice might form on the evaporator during lower outside temperatures. In
case there is enough ice to inhibit the air flow through the evaporator, an
automatic defrosting will start. As soon as the ice is gone, the heat pump
returns to its normal operation.
If the outside temperature is above +5 °C the defrosting will be
performed alongside continued heat production, however if the
temperature is lower, the defrosting is done by ways of a 4-way valve
turning the heat medium direction in the circuit so that the hot gas from
the compressor melts away the ice. The duration of the defrost cycle
depends on the actual outdoor temperature and the amount of frost on
the evaporator.
2.3.1

Range for heat pump without booster heater

In heating mode the heat pump switches off at approx. – 23 °C or +45 °C
outdoor temperature. The indoor unit or an external heat source then
takes over the heating and domestic hot water production. The heat
pump restarts if the outdoor temperature exceeds roughly – 17 °C or
falls below +42 °C.
In cooling mode, the heat pump switches off at roughly +45 °C and
restarts at roughly +42 °C.
Compress 5800iAW 12 E | OR-S | T – 6721871228 (2023/06)