INSTALLING THE PIPING

Installing Gray PVC Piping (Outside Cabinet)
Suction Section
1. Before installing, find the light gray gasket and
install into the pipe flange.
2. Place the lower end of the pipe into Hole #1.
3. Connect to suction port threaded union adapter
of the pump.
Discharge Section (with Flow Valve)
1. Install large clear gasket into the pipe flange
end. Align flange (see picture, right).
2. If not already installed, install the tassel
flow assembly into the clear pipe end of the
assembly. Place the tasselled end into opening
until metal ring is flush inside the gasket.
3. Shake the pipe slightly to allow the tassels to be
visible inside the clear section of piping.
4. Place the bottom end of the pipe into Hole #2.
5. Connect to discharge port threaded union
adapter of the pump. Tighten the union nut
securely. Be sure pipe is centred in Hole #2.
Tassel flow assembly
INTELLIFLO
Variable Speed Pump Demo Kiosk Operation and Set Up Instructions
®
3
Suction port
2
Hole # 1
5
Discharge port
TIP:
Be sure flanges of union and gasket are
flush before tightening the union nut.
NOTE:
Be sure gaskets do not fall off while
assembling discharge and suctions pipes;
the pump will leak.
1
Light gray
1
gasket
Clear gasket
4
Hole # 2